Adapting the appliance to the heating system
Display shown
HK2
Information
Flow Temp. Setpoint
Flow Temp. VF2
Status of pump
°mins lag/gain
HK2
Parameters
Flow Temp. Setpoint
Flow Temp. VF2
Status of pump
Status hydr. mixer
9.6. Menu C: Set parameters for the heating system
78
Description
For direct heating mode (e.g. Hydraulics diagram 1 or
C4
3), the upper menu is displayed.
The lower menu is only displayed if a buffer tank is
41 °C
used (e.g. Hydraulics diagram 2, 4 or 10 and when
30 °C
VR 60 is used, including repeatedly).
OFF
-183°min
Flow Temp. Setpoint: Flow temperature for the heat-
ing circuit
Flow Temp. VF2: Current flow temperature VF2.
C4
°mins lag/gain: The °mins lag/gain is the sum of the
41 °C
difference between TARGET flow temperature
29 °C
and ACTUAL flow temperature per minute. The
OFF
heat pump starts at a particular heat deficiency
(see energy balance control (¬ Ch. 9.4.2)).
Open
Status of pump: Indicates whether the pump is
turned on or off (ON/OFF).
Status hydr. mixer: The OPEN/CLOSED indication
describes the direction in which the control sys-
tem is driving the mixer. If the mixer is not acti-
vated, OFF appears.
If a VR 60 is connected, the lower menu appears sev-
eral times (for each heating circuit).