Vaillant geoTHERM Installation Instructions Manual page 112

Table of Contents

Advertisement

14
Technical data
Description
Heat pump performance data
B0/W35 DT 5K In accordance with
DIN EN 14511
- Heating output
- Power consumption
- Output figure/coefficient
of performance COP
B0/W35 DT 10K In accordance with
DIN EN 255
- Heating output
- Power consumption
- Output figure/coefficient
of performance COP
B0/W55 DT 5K In accordance with
DIN EN 14511
- Heating output
- Power consumption
- Output figure/coefficient
of performance COP
Interior noise level
(B0/W35 in accordance with EN 12102)
Installation location
- permitted ambient temperature
Application limits
At the same volume flow rates as for
the nominal output test under standard
nominal conditions with nominal vol-
ume flow rates and a spread of DT 3K in
the brine circuit and DT 5K in the heat-
ing circuit
14.1
Technical Data VWS
112
Unit
VWS 220/2
The following performance data is applicable to new units with clean heat exchangers.
kW
22,00
kW
5,00
-
4,40
kW
22,30
kW
4,70
-
4,60
kW
20,30
kW
6,60
-
3,10
dB(A)
63
°C
Operation of the pump outside the application limits results in the heat pump
being switched off by the internal control and safety installations.
VWS 300/2
VWS 380/2
29,80
38,30
6,50
8,50
4,60
4,50
30,30
37,80
6,30
8,00
4,80
4,70
26,80
36,20
8,80
11,70
3,00
3,10
63
63
Interior/dry
7 - 25
B-10/W25
B-10/W55
B-5/W62
B20/W62
B20/W25
Installation instructions geoTHERM 0020051574_04
VWS 460/2
45,90
10,00
4,60
45,50
9,70
4,70
42,30
14,10
3,00
65