2.1 FLUE SYSTEM

When installing a replacement boiler a new flue system must
be used. DO NOT re-use the existing boiler flue installation.
DESIGN
Individual air supply and flue outlet pipes are used as standard.
The material used for flue outlet &/or air inlet must be
muPVC (PVC-C) to BS 5255 and/or BSEN 1566-1 and BSEN
1329 of an internal diameter of 51mm. (i.e. nominal 50mm
diameter muPVC solvent weld waste pipe).
Marley muPVC (PVC-C) Solvent Weld Waste System
(50mm) and Polypipe System 2000 muPVC (PVC-C) solvent
weld waste (50mm) are the only systems approved for this
application.
18
SECTION 2 - INSTALLATION
The following pipes and fittings are approved:
Polypipe System 2000 muPVC solvent Weld Waste System
(50mm)
Poly Pipe Code
MU 301
4m length muPVC wastepipe 5/225
MU 313
50mm x 45 deg muPVC obtuse bend
MU 314
50mm x 92.5 deg muPVC swept bend
MU 310
50mm muPVC straigh coupling
MU 316
50mm x 92.5 deg muPVC swept pipe
Marley muPVC solvent Weld Waste System (50mm)
Marley Code
KP 304
50mm x 4m double spigot pipe
KP32
50mm x 45 deg bend
KSC3
50mm straight coupling
KB3
50mm x 88.5 deg bend
KT3
50mm swept tee