Assembly And Installation; Wall Assembly; Connection Of A Separate Dc Voltage Supply; Connection Of The Internal Relay Contact - MALUX INDUTEL IP Operating Manual

Weatherproof telephone
Table of Contents

Advertisement

Assembly and installation

Since all telephones have the same preset IP address, the network settings should be made
on the web server of the telephone before the telephone is assembled. The username and
password at the time of delivery should be changed for security reasons. The assembly of the
telephone should only be carried out by qualified specialist personnel.

Wall assembly

Assembly is carried out on a firm and even surface.
Fasten the telephone to the wall with four screws (of a size of up to Ø 8 mm).
Attach the LAN device connector plug provided to the LAN cable available onsite and connect
the device connector plug with the telephone.

Connection of a separate DC voltage supply

If a PoE supply is not available, the telephone can also be operated with a DC voltage of 24 V
to 48 V.
Take off the handset. Unscrew the keypad plate. Guide the supply line through the screwed
cable gland and put the two connecting leads onto the terminals 3 and 4 (any polarity). Fix the
supply line with the cable gland. Make sure that the cable connection to the keypad is plugged
in. Then place the keypad plate back onto the telephone and fasten it with four screws. Then
put the handset back.

Connection of the internal relay contact

Take off the handset. Unscrew the keypad plate. Guide the connection line through the
screwed cable gland and put the two connecting leads onto the terminals 1 and 2. Fix the
connection line with the screwed cable gland. Make sure that the cable connection to the
keypad is plugged in. Then place the keypad plate back onto the telephone and fasten it with
four screws. Then put the handset back.
Only use lines with a sheathing diameter of 5 mm to 9 mm, since the degree of protection
IP 66 is not ensured otherwise. If you wish to use a separate DC voltage supply and the relay
contact at the same time, you must use a four-core cable.
If a separate DC voltage supply and connection of the internal relay contact are not required,
it is to be ensured that the sealing element is in the screwed cable gland.

Terminal configuration

Relay
contact
DC voltage
supply
www.malux.se
5