Installation instructions for installers
Solar controller
CS 200
0010007286-001

Advertisement

Table of Contents
loading

Summary of Contents for Worcester CS 200

  • Page 1 Installation instructions for installers Solar controller CS 200 0010007286-001...
  • Page 2: Table Of Contents

    Table of contents 7.2.1 Function tests ......12 Table of contents 7.2.2 Monitored values ......12 7.2.3 Fault displays .
  • Page 3: Key To Symbols And Safety Instructions

    Key to symbols and safety instructions General safety instructions Key to symbols and safety instructions These installation instructions are intended for plumbers, heating engineers and electricians. Explanation of symbols ▶ Read the installation instructions (heat sources, modules, etc.) before installation. Warning symbols ▶...
  • Page 4: Product Description

    ▶ Correct any faults immediately. Product Description Product description • The CS 200 must be used in conjunction with the MS 200 to control a Solar heating system, in certain cases an MS 100 may also be combined. • After operating for 90 minutes, the solar controller has a power reserve of at least 8 hours.
  • Page 5: Temperature Sensor Characteristics

    Installation Disposal Rated power (excluding 9 mA ▶ Dispose of packaging in an environmentally responsible illumination) manner. BUS interface EMS 2 ▶ When replacing assemblies or components, dispose of the Permitted ambient temp. 0 °C to 50 °C old assemblies or components in an environmentally Protection class responsible manner.
  • Page 6: Electrical Connection

    Installation ▶ To avoid inductive interference: Make sure all low-voltage cables are routed separately from mains voltage cables (min. clearance 100 mm). ▶ In the case of external inductive interferences (e.g. from photovoltaic systems), use shielded cables (e.g. LIYCY) and earth the shield on one side. The shield should be connected to the building's earthing system, e.g.
  • Page 7: Basic Principles Of Operation

    Basic principles of operation ▶ Remove the solar controller by lifting upward. auto menu info 0010007391-001 Fig. 6 Control elements [1] fav key – Lists the favourites [2] man key – Deactivates the automatic change of the temperature displayed in the standard display 0010005431-002 [3] auto key –...
  • Page 8: Operating The Service Menu

    Commissioning Operating the service menu ▶ Turn the rotary control knob to highlight Continue and press the rotary control knob. Closing and opening the service menu The Display switches to the previous menu level. The solar controller operates with the modified setting. Opening the service menu ▶...
  • Page 9: General Commissioning Of The Solar Controller

    ( Chapter 5.3, page 9) 5.3.1 Commissioning the solar heating system 8. Check and, if necessary, adjust the settings in the service menu of the CS 200 solar controller and perform Menu item configuration ( Chapter 5.4, page 10) Start configuration wizard? 9.
  • Page 10: Additional Settings At Commissioning

    Shutdown / switching off System handover Menu item ▶ Enter the contact details of the responsible installer in the Type collector array 1 Diagnosis menu > Maintenance > Contact address, e.g. Question Answer / setting company name, phone number and address or e-mail What type of collectors are Flat-plate collector | address (...
  • Page 11 Service menu – Speed ctrl. solar pump...2 – Reset elapsed times – Gross collector area 1 – 2 – Set temp. Double Match F. – Type collector array 1 – Glycol content – Climate zone – Solar DHW – Start solar thermal system –...
  • Page 12: Solar System Settings

    Service menu Solar system settings 7.2.1 Function tests This menu can be used to test active system components individually. If Enable function tests is set to Yes in this menu, the normal heating operation is interrupted in the entire system. All settings are saved. The settings in this menu are only temporary and revert to the respective default settings as soon as the Enable function tests is set to No or the Function test menu is closed.
  • Page 13: Reset

    Thermal disinfection 7.2.7 Calibration Menu item Description  "Contact address" Contact address Menu item Description Time correction This correction ( – 20 ... 0 ... + 20 s) is Table 9 Settings in the Maintenance menu automatically carried out once a week (0 is Contact address default).
  • Page 14: Troubleshooting

    If the sensor values from liability. terminals of the collector matched, but the If a fault cannot be corrected, Worcester's Technical Support temperature sensor on the solar voltage values do not department (see back cover). module according to the table...
  • Page 15: Environmental Protection And Disposal

    Environmental protection and disposal Fault code - sub-code - [cause or fault description] Check the bottom cylinder If values do not match, temperature sensor according to replace the sensor the table ( Chapter 3, page 5) Check the voltage at the If the sensor values terminals of the bottom cylinder matched, but the...
  • Page 16 0330 123 9779 LITERATURE: 0330 123 9119 TRAINING: 0330 123 0166 SALES: 0330 123 9669 Worcester, Bosch Group Cotswold Way, Warndon, Worcester WR4 9SW. Tel. 0330 123 9559 Worcester, Bosch Group is a brand name of Bosch Thermotechnology Ltd. worcester-bosch.co.uk 6720830475...