Acer Iconia A1-810 Service Manual page 23

Hide thumbs Also See for Iconia A1-810:
Table of Contents

Advertisement

Item
Shock
Operating
Nonoperating
Random vibration
Operating
NOTE:
Applicable product safety standards specify thermal limits for plastic surfaces. The computer
operates well within this range of temperatures.
Hardware Specifications and Configurations
Metric
Amplitude: 105G
Duration: 2 ms
Wave form: Half-sine
Axes: ±X, ±Y, +Z
Test Time: 1 times per axis
Amplitude: 220G
Duration: 2 ms
Wave form: Half-sine
Axes: ±X, ±Y, ±Z
Test Time: 1 time per axis
Frequency: 10 ~ 500 Hz
Strength: 1.644 g
Spectrum:
10Hz 2.4*10-2g2/Hz
14Hz 4.2*10-1g2/Hz
20Hz 2.9*10-2g2/Hz
47Hz 6.4*10-3g2/Hz
115Hz 5.3*10-3g2/Hz
162Hz 1.8*10-3g2/Hz
192Hz 3.9*10-3g2/Hz
264Hz 7.5*10-4g2/Hz
500Hz 7.5*10-4g2/Hz
Test Duration: 2 hours in each axis (X, Y, Z)
Function test after each axis