MAIN LEVEL
Lamp
Setting
(cont.)
Setup
(cont.)
Special Set
Running Mode
Sys Info
Lamp On Time
DMX Linking
The Intimidator Beam 140SR can work with a DMX controller. Instructions for connecting and configuring this product for
DMX operation are in the User Manual. If you are not familiar with DMX, download the DMX Primer from www.chauvetdj.com.
Starting Address
To ensure full access to all channels available in each DMX mode, the highest recommended DMX address is 499.
Master/Slave Connection
The Intimidator Beam 140SR uses the DMX data connection for its Master/Slave mode. Information about configuring the
Intimidator Beam 140SR for Master/Slave operation is in the User Manual, which is available from the Chauvet website.
IRC-6 (Infrared Remote Control)
The Intimidator Beam 140SR can be operated with the CHAUVET IRC-6. For more information about the IRC-6,
download instructions for the IRC-6 or the Intimidator Beam 140SR User Manual from www.chauvetdj.com.
Gobos
Intimidator Beam 140SR QRG Rev. 4
QUICK REFERENCE GUIDE
PROGRAMMING LEVELS
On If DMX
On
Off If DMX
Off
Ignition
Delay
Low Power
Delay
Reset Lamp
Time
Lamp Power
Interval
Remain Time
Sensitivity
Reset
Factory Set
Ver:
DMX Address
Remain Time
DESCRIPTION
NO
Turns lamp on when DMX signal is detected
YES
NO
Turns lamp off when DMX signal is lost
YES
Selects duration of delay between product powering
000–255
on and lamp turning on
Selects the duration of delay between shutter closing
000–255
and lamp enters low power mode
NO
Resets lamp time counter (for when lamp is replaced)
YES
132
Select if installed lamp is 132 W Osram HRI
140
Select if installed lamp is 140 W Osram HRI
10–250
Defines number of hours between maintenance
NO
Resets maintenance timer
RESET
001–100
Sets sound sensitivity
Resets the product
Loads factory defaults
V_
Displays the software version
_ _ _ _ _ _ _
Displays the current running mode
_ _ _
Displays the current DMX address
_ _ _ _ _
Displays how long the lamp has been running
_ _ _ _ _
Shows amount of time remaining in maintenance cycle