Refrigerant Piping Work - Mitsubishi Heavy Industries SRK63ZR-S Technical Manual

Inverter wall mounted type residential air-conditioners split system air to air heat pump type
Hide thumbs Also See for SRK63ZR-S:
Table of Contents

Advertisement

• All indoor units must be models designed exclusively for R410A. Check connectable indoor unit models in a catalog, etc. (A wrong indoor unit, if connected into the system, will impair proper system operation)
1. HAULAGE AND INSTALLATION
When a unit is hoisted with slings for haulage, take into consideration the offset of its gravity center position.
CAUTION
If not properly balanced, the unit can be thrown off-balance and fall.
1) Delivery
• Deliver the unit as close as possible to the installation site before removing it from
the packaging.
• When you have to unpack the unit for a compelling reason before you haul it to
the installation point, hoist the unit with nylon slings or ropes and protection pads
so that you may not damage the unit.
2) Portage
• The right hand side of the unit as viewed from the front (Fan side) is heavier. A
person carrying the right hand side must take heed of this fact. A person
carrying the left hand side must hold with his right hand the handle provided on
the front panel of the unit and with his left hand the corner column section.
3) Selecting the installation location
Be sure to select a suitable installation place in consideration of following conditions.
• A place where it is horizontal, stable and can endure the unit weight and will not allow vibration transmittance
of the unit.
• A place where it can be free from possibility of bothering neighbors due to noise or exhaust air from the unit.
• A place where the unit is not exposed to oil splashes.
• A place where it can be free from danger of flammable gas leakage.
• A place where drain water can be disposed without any trouble.
• A place where the unit will not be affected by heat radiation from other heat source.
• A place where snow will not accumulate.
• A place where the unit can be kept away 1m or more from TV set and/or radio receiver in order to avoid any
TV set or radio receiver interference.
• A place where good air circulation can be secured, and enough service space can be secured for maintenance
and service of the unit safely.
• A place where the unit will not be affected by electromagnetic waves and/or high-harmonic waves generated
by other equipment.
• A place where chemical substances like sulfuric gas, chloric gas, acid and alkali (including ammonia), which
can harm the unit, will not be generated and not remain.
• If a operation is conducted when the outdoor air temperature is -5 or lower, the outdoor unit should be
installed at a place where it is not influenced by natural wind.
• A place where strong wind will not blow against the outlet air blow of the unit.
• A place where stringent regulation of electric noises is not applicable.
Do not install the unit in places which exposed to sea breeze (e.g. coastal area) or calcium chloride (e.g. snow
melting agent), exposed to ammonia substance (e.g. organic fertilizer).
4) Caution about selection of installation location
(1) If the unit is installed in the area where the snow will accumulate, following measures are required.
The bottom plate of unit and intake, outlet may be blocked by snow.
1 Install the unit on the base so that the bottom is
higher than snow cover surface.
Since drain water generated by defrost control may freeze, following measures are required.
• Do not execute drain piping work by using a drain elbow and drain grommets (accessories).
[Refer to Drain piping work.]

2. REFRIGERANT PIPING WORK

(Take particular care in carrying in or moving the unit, and always perform such an operation with two or more persons.)
Pad
Heavy
2 Install the unit under or provide the roof on site.
(2) If the unit can be affected by strong wind, following measures are required.
Strong wind can cause damage of fan (fan motor), or can cause performance degradation, or can trigger
anomalous stop of the unit due to rising of high pressure.
1 Place the unit outlet side is turned to the wall.
Over 500mm
Over 500mm
5) Installation space
• Walls surrounding the unit in the four sides are not
acceptable.
• There must be a 1-meter or larger space in the above.
• When more than one unit are installed side by side,
provide a 250mm or wider interval between them as a
service space. In order to facilitate servicing of
controllers, provide a sufficient space between units so
that their top plates can be removed easily.
• Where a danger of short-circuiting exists, install guide
louvers.
• When more than one unit are installed, provide sufficient
intake space consciously so that short-circuiting may not
occur.
• Where piling snow can bury the outdoor unit, provide
proper snow guards.
6) Installation
1 Anchor bolt fixed position
Model 63(21)
50.6
12
Intake
Outlet
89
510
201
800
71
2 Notes for installation
Fasten with bolts
(M10-12)
Use a long block to extend the width.
Use a thicker block to anchor deeper.
• In installing the unit, fix the unit's legs with bolts specified on the above.
• The protrusion of an anchor bolt on the front side must be kept within 15mm.
• Securely install the unit so that it does not fall over during earthquakes or strong winds, etc.
• Refer to the above illustrations for information regarding concrete foundations.
• Install the unit in a level area. (With a gradient of 5mm or less.) Improper installation can result in a
compressor failure, broken piping within the unit and abnormal noise generation.
2 Install so the direction of the air from the
blowing outlet will be perpendicular to the
direction of the wind.
Wind
direction
Wind
direction
(mm)
Model 63(21)
Model 71(24), 80(28)
Example
installation
I
II
III
IV
I
II
III
Size
L1
Open
280
280
180
Open
Open
500
L2
100
75
Open
Open
300
250
Open
L3
100
80
80
80
100
150
100
L4
250
Open
250
Open
250
250
250
The height of a wall is 1200mm or less.
L
Intake
3
(
service
)
L
2
space
L
4
Intake
Outlet
L
1
Model 71(24), 80(28)
60
Intake
15
Outlet
150
580
150
880
87.9