3. Prepare Gas supply line and Electrical outlet
The gas supply line and electrical outlet must be
located in the shaded area.
Place Gas Supply
Line and Electrical
Outlet Here
7 1/2"
7 1/2"
13 1/8"
4 1/2"
13 1/8 "
4 1/2"

Procedure

Installation of anti-tip bracket

1. Adjust height of range and level by rotating the ad-
justable leg supports on the bottom of the range,
using 1-1/4" (32 mm) wrench.
2. Locate bracket position as shown below.
3. Secure bracket with 2 screws to the floor or to the wall.
Depending on floor or wall material use wood or an-
chorless concrete screws (included). Concrete screws
require a 3/16" masonry bit.
Screws should provide firm attachment into solid wood
or flooring. Do not attempt to anchor into drywall.
6
3 1/2"
3 1/2"
4 1/2"
4"
3 7/8"
4 1/2"
4"
3 7/8"
30"
30"
4. Prepare Walls and Floor
Seal any holes in the walls or floor. Remove any ob-
structions (extra electrical or gas connections, etc.)
so that range will rest against wall properly.
tips:
· Tape warming drawer shut to keep it from ope-
ning while installing the range.
· During installation, place a portion of the box or
a piece of cloth under the range to protect floors.
· To make range lighter and easier to handle,
remove door (see instructions in "Use and Care
Manual").
*Instructions were determined using standard American cabinets. Standard
base cabinets measure 36" (91.4 cm) high x 24" (61 cm) deep . Cabinets
over the cooking surface and cabinets adjacent to those over the cooking
surface measure 13" (33 cm) deep from backwall. If nonstandard cabinets
are used, care should be taken to alter dimensions accordingly.
** 12 mm clearance from range sidewall to cabinet required in Canada.
connect Gas and Electrical supply
Important note for lP users: The range is shipped
from the factory for use with natural gas. For use
with propane (LP) gas, your range must first be con-
verted using the LP conversion kit.
The gas connection is located below the back panel
of the range (page 7). It is accessible through the
warming drawer access panel or from the back of
the range. To reach access panel, remove warming
drawer.
Shut off main gas supply valve before disconnecting
the old range and leave it off until the new hook-up
has been completed. Don't forget to relight the pi-
lot on other gas appliances when you turn the gas
back on.
The range can be installed using rigid pipe or a CSA
International-certified flexible metal appliance con-
nector. If using a flexible connector, always use a
new connector.
Apply pipe joint compound or Teflon** tape appropri-
ate for use with LP gas and Natural gas around all
male pipe threads to prevent leaks.
If not already present, install gas shut off valve in an
easily accessible location. Make sure all users know
where and how to shut off the gas supply to the
range.
notE: The installer should inform the consumer of
the location of the gas shutoff valve.