CONNECTION INSTRUCTIONS

Connection of power supply

The operating voltages for the station unit are obtained by:
 supplying the Power supply unit with 110/220 V AC 50/60 Hz. The power required
is approx. 100 W. External gas-tight accumulators can be maintenance-charged.
 external supply of 13.8 V DC. Power required approx. 100 W.
When connecting to a mains power supply:
 before connection check that the rating plate on the Power supply unit indicates
that the correct unit has been supplied
 connect the mains cable that has been laid to the site, to the connector marked
13-15 V DC on the rear of the station unit.
When connecting to a battery power supply:
 Prepare the cable for the battery supply as shown in chapter 8.
 Connect to the connector marked 13-15 V DC on the rear of the station unit.
Cable area required: The voltage drop from the battery must be less than 0.1 V at 20
A.

Connection of antenna

 Connect the antenna cable to the connector marked ANT(Tx) on the rear of the
station unit.
Please note that other alternatives are available, depending on the final configuration
of the antenna and filter system.

Connection of signal cables

 Connect the telephone line from the "control unit" to the connector marked LINES
OUT, on the rear of the station unit.
 Make sure that the lightning protection kits are installed properly.
 Control the connections of "Alarm unit" if applicable.