6. ENVIRONMENT
Operating Temperature: 0c~40c (Ambient)
Operating Humidity: Ta= 35 °C, 90%RH (Non-condensing)
Operating Altitude: 0 - 14,000 feet (4267.2m)(Non-Operating)
7. DIMENSIONS (Physical dimension)
Dimensions with stand:
1024.4mm(W) x 669.2mm(H) x 243.4mm(D) inches
Dimension without stand:
1024.4mm(W) x 665.7mm(H) x 99.9mm(D) inches
8. WEIGHT (Physical weight)
a. Net
45.11 ±0.5 kg
b. Gross 53.40 ±1.0 kg
Precaution
Please pay attention to the followings when you use this PDP module.
1. OPERATING PRECAUTIONS
(1) The spike noise causes the mis-operation of circuits. It should be lower
than following voltage :
V=±200mV(Over and under shoot voltage)
(2) Response time depends on the temperature. (In lower temperature, it
becomes longer.)
(3) Brightness depends on the temperature. (In lower temperature, it becomes
lower.)And in lower temperature, response time (required time that
brightness is stable after turned on) becomes longer.
(4) Be careful for condensation at sudden temperature change. Condensation
makes damage to polarizer or electrical contacted parts. And after fading
condensation, smear or spot will occur.
(5) When fixed patterns are displayed for a long time, remnant image is likely
to occur.
CONFIDENTIAL – DO NOT COPY