Analog Mode
CAUTION: Open loop signal voltage must not exceed 25 VDC. If the signal voltage is greater than
25 VDC, power down the signal source prior to connection.
Connecting an analog signal device
Disconnect AC power to the pump. Remove the
four screws from the terminal block cover and
remove the cover. Remove the cord nut and
bushing from the terminal block cover. Remove
the terminal block from the connector. Slide the
nut and bushing over the external control cable
and insert the cable through the terminal block
cover. Strip 1/4" insulation from conductors and
connect the positive side to terminal 5 and the
negative side to terminal 8. (See Figure 8 and
the schematic to the right.)
STOP Function
The EHE series pump also includes a STOP function that allows an external signal to stop the
operation of the pump.
A switch or solid-state device capable of switching 5 VDC at 2 mA can be connected to terminals 6
(positive) and 8 (negative) of the terminal block. Closing this circuit temporarily interrupts pump
operation. Opening this circuit resumes pump operation. If the pump is operating in external digital
mode, any pulses received while the pump is stopped will be saved (up to a maximum of 255). When
pump operation resumes, saved pulses will allow the pump to "catch up" by producing the correct
number of pump strokes that should have occurred while it was stopped. The 'Over' indicator will
light up if the pump receives pulses while in the 'Stopped' condition (see Figure 8 and the schematic
below).
3.6

AC Power Interruption

If AC power is interrupted, the pump will power up as shown below:
State preceding power OFF
WAIT
Run Manual
Run external
Set EXTernal mode
Set EXTernal values
1 2 3
Power
State following power ON
WAIT
Run manual
Run external
WAIT
WAIT
22
4 5 6 7 8
_
+
Analog Input