(6) Press the EXT key to enter the memory selections and return to
the "dIG" set menu.
(7) Press the START/STOP key to confirm the Digital Operation
selection and return to the WAIT mode. The SET backlight will
go out and the WAIT light will illuminate.
(8) Digital Input Selection:
(NOTE: Pump is pre-set at factory with both MULT or DIV set to
1. The default Digital mode is preset to DIV.)
Press the EXT and  keys simultaneously. The display will
show "/ 1" (Dividing mode) and the SET backlight will appear.
(9) Pressing the EXT key toggles the mode of operation between "/"
(DIV) and "X" (MULT).
Once the desired mode of operation is displayed ("X 1" for
MULT or "/ 1" for DIV), set the value needed to be multiplied
or divided.
(10) Setting the Stroke Rate:
Set the desired multiplier or divider value using the  and 
keys.
The allowable range is 1-999 and the default setting from the
factory is 1.
18