(5) Setting the Input Current (mA) of SET point 1:
Use the and keys to set the input current (mA) of SET point
1. The value will increase with the key and decrease with
the key. The numerical value will change slowly by 0.1mA if the
keys are pressed briefly, but will increment rapidly if they are
held for more than 3 seconds.
The allowable range is 0.0-20.0mA and the default setting from
the factory is 4.0mA.
(6) Press the EXT key to confirm the current value of SET point 1
and move to the pump speed (SPM) setting of SET point 1. "P
0" will be the default setting (Pump speed=0spm) and the SET
and 1 will remain backlit.
(7) Setting the Stroke Rate of SET point 1:
Set the stroke rate corresponding to the current setting of SET
point 1 using the and keys.
The allowable range is 0-360 spm and the default setting from the
factory is 0 spm.
(8)
Press the EXT key to confirm the pump speed value of SET point
1 and move to the Current Input setting of Set point 2. The
backlight behind SET will remain, but the light behind 1 will go
off and 2 will become backlit. The default display will show
A20.0.
(9) Setting the Input Current (mA) of SET point 2:
Use the and keys to set the input current (mA) of SET point
2. Do NOT set the value equal to SET point 1 or an error (ERR1)
will occur.
The allowable range is 0.0-20.0mA and the default setting from
the factory is 20.0mA.
(10) Press the EXT key to confirm the current value of SET point 2
and move to the pump speed (SPM) setting of SET point 2.
"P360" will be the default setting (Pump speed=360spm) and the
SET and 2 will remain backlit.
15