If you do not follow these instructions exactly, a fire or
explosion may result causing property damage, personal injury
or loss of life.
FIRE OR EXPLOSION
Improper installation, adjustment, alteration, service or
maintenance can cause property damage, personal
injury or loss of life. Refer to the installation instructions
and/or owner's manual provided with this appliance.
Installations, repairs and preventive maintenance should
be done by a qualified Service Technician only.
POSSIBLE INJURY OR DEATH
If the user of this appliance fails to maintain it in the condition in
which it was shipped from the factory or if the appliance is not used
solely for its intended purpose or if appliance is not maintained in
accordance with the instructions in this manual, then the risk of a fire
and/or the production of carbon monoxide exists which can cause
personal injury, property damage or loss of life.

CARBON MONOXIDE POISONING

Doors must be properly sealed and draft cap and assemblies
must be adjusted and sealed correctly to prevent carbon
monoxide from entering coach.
Combustion air must NOT be drawn from within any living area.
DO NOT vent exhaust into living area or outside into an enclosed
porch area.
DO NOT vent any other appliance with venting systems serving
the furnace.
DO NOT allow snow or any objects to block exhaust system of
furnace.
POSSIBLE INJURY OR DEATH
Do not install screens over the intake air or exhaust vents for any
reason. Screens will become restricted and cause unsafe furnace
operation. Accessories are being marketed for RV products which we
do not recommend. For your safety, only factory authorized parts are to
be used on your furnace.
POSSIBLE INJURY OR DEATH
Do not use this appliance if any part has been under water. A flood-
damaged furnace is extremely dangerous. Attempts to use the furnace
can result in fire or explosion.
A qualified service agency should be contacted to inspect the furnace
and to replace all gas controls, control system parts, electrical parts
that have been wet or the furnace if deemed necessary.
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
Listed below are several safety related items that you the (owner)
should follow each heating season to assure continued safe operation
of the furnace. A periodic inspection of the furnace by a qualified
service agent is also recommended.
Inspect furnace venting. Venting must be free of obstructions,
void of soot and properly terminated to the atmosphere. Make
sure that the vent assembly is positioned tight against outer door.
Periodically inspect the vent for obstructions or presence of soot.
Soot is formed whenever combustion is incomplete. This is your
visual warning that the furnace is operating in an unsafe manner.
If soot is present, immediately shut furnace down and contact
your dealer or a qualified service person.
Keep furnace clean. More frequent cleaning may be required due
to excessive lint from carpeting, bedding material, pet hair etc. It
is imperative that control compartments, burners, and circulating
air passageways of the appliance be kept clean and
unobstructed.
The motor is permanently lubricated and requires no oiling.
Keep the furnace area clear of any combustible materials,
gasoline, or other flammable vapor and liquids.
Before operating furnace, check the location of the furnace vent to
make sure it will not be blocked by the opening of any door on the
trailer. If it can be blocked, do not operate the furnace with the
door open.
Do not restrict the flow of combustion air or the warm air
circulation to the furnace. To do so could cause personal injury
and/or death.
Never operate the furnace if you smell gas. Do not assume that
the smell of gas in your RV is normal. Any time you detect the
odor of gas, it is to be considered life threatening and corrected
immediately. Extinguish any open flames including cigarettes and
evacuate all persons from the vehicle. Shut off gas supply at LP
gas bottle. (See safety notice in this manual).
Immediately shut furnace down and call a service agency if
furnace cycles erratically or delays on ignition.
Never attempt to repair the furnace yourself. Seek the help of a
qualified service person.
Never restrict the ducting installed by your trailer manufacturer.
To do so could cause improper furnace operation.
Do not install air boosters in the duct system. Such devices will
cause the furnace to cycle on limit and to have erratic sail switch
operation.
Clothing or other flammable material should not be placed on or
near the appliance.
Always follow the Operating Instructions. Do not deviate from the
step-by-step procedures.
When considering add-on rooms, porch or patio, attention must
be given to the venting of our furnace. For your safety, do not
terminate furnace vent inside add-on rooms, screen porch or onto
patios. Doing so will result in products of combustion being vented
into the room or occupied areas.
 In any installation in which the vent of the appliance can be covered
due to the construction of the RV or some special feature of the RV
such as slide out, pop-up etc. Always insure that the appliance
cannot be operated by setting the thermostat to the positive "OFF"
position and shutting off all electrical and gas supply to the
appliance. Never operate furnace with vent covered.
DO NOT use petroleum or citrus type cleaner on plastic parts, as
damage may occur.