8.Printed Circuit Board (PCB)

8.1 Exchange of PCB
At exchange of the PCB, chassis complete with PCB shall always be exchanged.
Operations at the exchange of PCB:
Open the control panel by....
A
B
C
D
There are 4 types of control panels,
-
A,B,C,D, see pictures to the left.
For type A and B: Loosen the pivot pin
-
from above.
-
For type C and D: Loosen the doors
upwards. Unscrew the pivot pin from
below.
For products with halogen light with
-
transformer: Disassemble the top by
loosening the screws at the back and
then pull the top forward in order to
enable it to pass by the pivots. This
action must be taken because the
halogen transformer is too large to be
removed through the front.
-
Loosen the front panel by way of the
snap fixings at the upper side of the
panel. The panels of type B and D
have also fixing screws on the lower
edge, see picture below.
Secure the door by screwing back the
-
pivot pin or by tape.
Loosen the chassis by first snapping
-
loose possible lamp glass.
-
Bend the front part carefully while
simultaneously snapping the chassis
from its fixings by pulling it in a
downward direction.
The panel type B has also an inner
-
snapping which has to be loosened,
see picture below.
10