H-11
PID output characteristic
PID controller given signal
H-12
sources
PID controller feedback signal
H-13
source
H-14
PID preset frequency
PID preset frequency running
H-15
time
H-16
PID keypad digital given
H-17
PID channel gain
Sensor maximum measuring
H-18
range
H-19
Proportion gain P
H-20
Integral time constant I
H-21
Differential gain D
H-22
Sampling period
H-23
PID control deviation limit
H-24
Starting threshold value
H-25
Sleep threshold value
H-26
Alarm upper limit value
H-27
Alarm lower limit value
Sensor disconnection
H-28
detection
Sensor disconnection alarm
H-29
operation selection
H-30
Upper limit threshold
H-31
Lower limit threshold
H-32
Program running mode
0: Positive characteristic
1: Negative characteristic
0: Keypad potentiometer
1: PID keypad digital given
2: External terminal VS1:0-10V
3: External terminal AS: 4 20mA
4: External terminal VS2
5: External pulse signal
6: RS485 interface
0: External terminal VS1:0-10V
1: External terminal AS: 4 20mA
2: External terminal VS2 ( bipolar
invalid)
4: External pulse signal
0.00Hz upper limit frequency
0.0 6500.0s
0.0 100.0%
0.01 5.00
1.0 100.0
0.1 100.0
0.1 100.0s
0.0 10.0
0.01 60.00s
0.0 20.0%
0.0% Sleep threshold value
Starting threshold value 100.0%
Alarm lower limit value 100.0%
0.0% Alarm upper limit value
0.0 20.0%
0: continue running
1: Stop
lower limit threshold 100.0%
0.0% Upper limit threshold
0: Single cycle running (time by
second)
1: Continuous cycle running
2: single cycle, continuous running
(time by second)
3: Single cycle running (time by minute)
4: Continuous cycle (time by minute)
5: Single cycle, continuous running
(time by minute)
28
0
107
1
108
1
108
0.00Hz
108
●
0.0s
108
●
50.0%
109
●
1.00
109
●
100.0
109
●
20.0
109
●
2.0s
109
●
0.0
109
●
0.10s
110
●
0.0%
110
●
0.0%
110
●
100.0%
110
●
100.0%
110
●
0.0%
110
●
0.0%
111
●
0
111
●
100.0%
111
●
0.0%
111
0
111
30BH
30CH
30DH
30EH
30FH
310H
311H
312H
313H
314H
315H
316H
317H
318H
319H
31AH
31BH
31CH
31DH
31EH
31FH
320H