Connect the circuit breakers (port and port engine compartments) and check that
the windlass circuit breaker is triggered.
Caution - Battery coupling principle:
• The coupling between the service battery pack and the engine battery
is triggered when the voltage on one of the parks exceeds 13.2 V.
• The coupling is maintained until the park voltage falls below 12.8 V.
• When the voltage is below 12.8 V, the coupling is interrupted and the
engine battery is then isolated from the service park
• The BACKUP/START-UP circuit breaker enables the
battery parks to be coupled IF ONE PARK IS INSUFFICIENT.
It must always be disconnected as soon as the engine is running.
Fuse panels:
The 3 fuse panels are positioned as follows:
1 under the chart table in the saloon,
.
1 in the rear port engine compartment
1 in the starboard passage hanging closet.
The content of each box is detailed on the lid