Summary of Contents for Airwell RWV04

  • Page 1 WIRE CONTROLLER OPERATION MANUAL RWV04 Contents Parts and Functions Operation Installation Of Wire Controller No. 0150513925 Please read this manual carefully before using Keep this operation manual for future reference...
  • Page 2 Parts and Functions Key instructions for the wired controller *Up direction key: It provides temperature rise function in the mode switching interface; if this key is pressed in the menu interface, the cursor moves upward; It raises the numerical value when adjusting value. *Left function key: According to the function prompt above the key, it provides mode switching function in the mode interface and return function in the menu interface.
  • Page 3 Parts and Functions *Right function key: According to the function prompt above the key, it provides swing on/off function or air speed (when both the left-right and up-down options are not selected in the air direction setting interface) switching in the mode interface;...
  • Page 4 Parts and Functions *Online units display area: it displays the number of the units controlled by one wired controller *Special function/fault icon display area: such as weekly timer, Swing, sleep, children lock, force, air exchange and energy conservation; each icon corresponds to a function; if a fault appears, the fault icon is displayed.
  • Page 5 Parts and Functions Explanation of the icons of the wired controller Intelligent mode Time setting Heating mode Weekly timer Cooling mode Sleep Dehumidification mode Left-right swing Fan only mode Up-down swing Energy conservation function Swing function Fault Air change Force Children lock Mute Health...
  • Page 6 Operation Weekly timer setting: 1. Proceed with main interface * Menu * Weekly timer * "Enter" to enter, which is shown in Figure 1; When the cursors is at “ ”, press “Enter” key to add a group of timing information; non-initial setting may be displayed as shown in Figure 2;...
  • Page 7 Operation 3.Time setting of timing switch After the timing items for week have been set, each group of set timing information displays 5 seconds cyclically; when it is displayed in the timing information group, press the “Downward” key to initiate the time setting of the timing switch of the current group;...
  • Page 8 Operation Figure 5 6. Prior to setting of weekly timer, please make time setting through main interface* Menu* Time interface. 7. The slave unit of the wired controller has no setting of weekly timer. 8. Weekly timer setting done, it needs to exit the weekly timer interface to execute the order.
  • Page 9 Operation Service setting 1. Proceed through main interface*Menu*Other*enter password*press “Enter” key*Service Set*press “Enter” key to initiate the setting, which is shown in Figure 7. Figure 7 Figure 8 2. Password setting Common users are provided with a four-digit password which is initially 1234;...
  • Page 10 Operation If the new password has been set successfully, a window prompting “New password set Successfully*”, as shown in Figure 11 will appear; press “Enter” or “Cancel” to return to the previous menu. Figure 11 Figure 12 3.Restore the initial password Select “Password recovery”...
  • Page 11 Operation A common user can view the current faults and historic faults; a high-class user can view 10 historic faults, using the “downward” key and “upftward” key. If a common user presses the “downward” key, a window as shown in Figure 15; a high-class user can enter his/her password to Figure 15 view ten historic faults.
  • Page 12 Operation Sleep setting Figure 17 Proceed through main interface Menu Sleep press “Enter” key to initiate this mode; The default state is shutdown. Use the up ,down, left and right keys to adjust the cursor; The location where the cursor stays has the circle flickering; press the “Enter” key to select the time and switch between on/off.
  • Page 13 Operation **** Unit number setting (This function is intended for debugging by technical personnel. The wired controller No. with no permission of address setting by indoor DIP switch setting displays grey, with access to checking and no access to changing the communication No.) Figure 18 Figure 19...
  • Page 14 Operation The location where the cursor stays has the circle flickering; use the leftward and rightward keys to adjust the cursor; press the cursor where it stays to select ; indicates “selected” and indicates “unselected”. Figure 20 Figure 21 ECO setting Proceed through main interface*Menu*ECO*press the “Enter”...
  • Page 15 Operation Additional functions Figure 22 Proceed through main interface Menu Addition press “Enter” key to initiate. The default state is shutdown. Ventilation: Some models have the air ventilation and some models do not. For those models that do not have this function, the ventilation setting will not be usable.
  • Page 16 Operation Special parameters This function is a reserved function and is temporarily in color grey Filter screen cleaning If the state indication area of the main interface displays “filter ”, filter cleaning shall be performed. When “filter” is being displayed, keep both the upward and downward keys pressed down for 5 seconds to cancel the “filter”...
  • Page 17 Operation Special set Figure 24 1.Special set is only effective to some types, with order ineffective if no such function equipped in the corresponding indoor units. 2.When powered on, the default static pressure grade is 1 and no rated value displayed; when communication stabilized (about 3 minutes later), static pressure and rated state can be checked.
  • Page 18 Operation Detailed information (the common user password is required for access) Proceed through main interface Menu other enter the password Details press “Enter” to initiate. 063 is the address of the wired controller inside the group; if one unit is controlled by one wired controller, the default address is 01;...
  • Page 19 Operation Auto recovery: if this function is on, the state before power failure will be in the memory; after restoration of power failure, the unit will continue operating in the state as before the power failure. If this function is off, the state will not be memorized;...
  • Page 20 Operation Wiring connections of wire controller: Indoor 1 Indoor 2 Indoor N Indoor 15 Indoor 16 (master unit) Wire controller Wire controller Wire controller Wire controller Wire controller A B C A B C A B C A B C A B C Control wiring A B C...
  • Page 21 Installation Of Wire Controller Installation of wire controller: 1. Pass the communication cable through the hole of the concealed box 2. Pass the cable through the back cover of the wired controller at the place No.1 3. Mounted the back cover on the concealed box by screws 4.