Fig. 5
The earth connection is compulsory in terms of the law. Should there be no cable and/or plug on the equipment,
use suitable absorption material for the working temperature as well, as indicated on the matrix plate. Under no
circumstance must the cable reach a temperature above 50 °C of the ambient temperature.
Should a direct connection to the network be required, it will be necessary to interpose an omnipolar switch with
minimum aperture between the 3 mm. contacts, dimensioned to bear the plate load and it must follow the standards
in force (the yellow/green earth cable must not be interrupted by the switch). The plug or omnipolar switch must be
easily reached on the installed equipment.
The manufacturers decline any responsibility in the event of non-compliance with what is described above and the
accident prevention norms not being respected and followed.
If the mains cable becomes damaged, replace it immediately with a cable or special cable set obtained from the
manufacturer or from after sales service.
Adaptation to various types of gas
(Fig. 6) Should the appliance be pre-set for a different type of gas than that available, proceed as follows:
Fig. 6
51
CABLE-CLAMP