Chapter 2 enGIne
CheCk and adjuStment OF the InjeCtOr
CheCk and adjuStment OF the InjeCtIOn OpenInG preSSure
1. Mounting on injector in tester.
2. Handle of the tester is operated at 1time per second.
3. Indicator of the manometer is slowly rising and indicator shakes during injection. After looking at starting
shaking points of the indicator, check whether opening pressure is standard value.
Standard
preSSure
LImIt preSSure
4. The case which is defective, disassemble the injector and replace the thickness of the shim. And then
injection opening pressure adjusts standard value.
Be careful when disassembling the injector does not enter dust etc.
5. If you can't adjust injection pressure despite replace a thickness of the shim, injector replaces the assembly.
2
-
100
3015r(h)/3515r(h)/4015r(h)/F36r(h)/F42r(h) traCtOr
OpenInG preSSure
adjuStInG preSSure
warnInG
Standard value
standard value +5~10 kg/cm
Above standard value -10kg/cm
2
2
42hw-201601