Self-Diagnostic Function; Self-Diagnostic Display; How To Enter The Self-Diagnostic Function; Cassette Mechanism Test (For Error Code H01, H02, H03, F01) - Panasonic SA-AK633P Service Manual

Table of Contents

Advertisement

12 Self-Diagnostic Function

12.1. Self-diagnostic display

This unit is equipped with a self-diagnostic display function which, will display an error code corresponding to the problem occuring.
Use this function when performing checking maintenance on the unit.

12.2. How to enter the Self-Diagnostic Function

12.3. Cassette Mechanism Test (For error code H01, H02, H03, F01)

1. Press "TAPE, DECK 1/2" to select Deck 2.
2. Load a cassette tape with the erasure prevention tab, remove from left side only and close the cassette holder.
3. Press "FAST FORWARD MEMORY" (Tape will be stop after 2 seconds)
4. Load a cassette tape with the erasure prevention tab, remove from right side only and close the cassette holder.
5. Press "REVERSE FM MODE/BP" (Tape will be stop after 2 seconds)
6. Load a pre-recorded tape with both side record tabs intact and close the cassette holder.
7. Press "PLAY/TUNE/TIME ADJ UP" (After TPS function, tape will stop automatically)
8. Press "REC/STOP" (Tape will not move)
9. Press "STOP/TUNE MODE" to indicate Error code.
· If several problem exist, error code will change each time when "n /STOP" is pressed.
(e.g. H01 → H03 → F01 .....etc.)
10. Press "TAPE, DECK 1/2" to select Deck 1.
11. Repeat step 2 to 9 to test Deck 1. (Tape Deck 1 will not check H02 because of no recording function)
12.4. CD Mechanism Test (F15, F26, F16, F17, F27, F28, F29, F30, H15 &
H16)
1. Press
(set to CD Mode) on main unit.
2. Press "CD DIRECT PLAY (1)" and
button on main unit.