SPECIFICATIONS
44" LEFT-TO-RIGHT
NOTE 1:
THE MAXIMUM DOOR HEIGHT MAY BE
REDUCED BY THE ADDITION OF OPTIONAL
DOOR BRACKETS. MAXIMUM HEIGHTS OF
91", 89" & 87" ARE AVAILABLE.
NOTE 2:
VENTILATION DUCT ADAPTERS ARE
ADJUSTABLE FROM 51-1/2" TO 54".
NOTE 3:
THE DRIVE ASSEMBLY AND GUARD
MAY BE INSTALLED ON EITHER END
OF THE UNIT. INSTALLATION ON THE
UNLOAD END IS STANDARD. IF
INSTALLED ON THE LOAD END,
PLEASE ENSURE ANY SCRAP SINKS
IN THE TABLING ARE AT AN ADEQUATE
DISTANCE TO PROVIDE FOR CLEARANCE
OF THE DRIVE ASSEMBLY.
NOTE 4:
NOTE 4:
ALL DIMENSIONS FROM THE
ALL VERTICAL DIMENSIONS MAY
FLOOR CAN BE INCREASED
VARY DUE TO THE ADJUSTABLE
1 3/4" USING THE MACHINE'S
FEET.
ADJUSTABLE FEET.
E1
E2
W
20 5 8 in
DET
(NOTE 4)
3 3 4 in
17 1 8 in
*Applies to steam heated units
** Chemical sanitizing units only
E1
MAIN ELECTRICAL CONNECTION (1.375" DIA HOLE)
E2
BOOSTER HEATER ELECT. CONNECTION (1.375" DIA)
W
MAIN INLET WATER CONNECTION (1/2 NPT-F)
D
DRAIN CONNECTION (1-1/2" NPT-F)
DET
DETERGENT BULKHEAD ACCESS (.875" DIA HOLE)
SAN**
SANITIZER INLET TO RINSE (1/8" NPT-F)
1
V1
CP
(NOTE 4)
(NOTE 4)
44" MACHINE DIMENSIONS
E2
W
E1
D
TABLE to TABLE
44 in
63 3 8 in
51 1 2 in MIN
(NOTE 2)
23.50
21 in
E1
E2
W
RA
DET
CP
D
C*
6 1 8 in
11 1 2 in
44 1 8 in
RA
RINSE AID CONNECTION TO RINSE (1/8" NPT-F)
CP
CONDUCTIVITY PROBE ACCESS (.875" DIA HOLE)
S*
STEAM TO WASH TUB HEATING COIL (3/4" NPT-F)
C*
CONDENSATE RETURN (3/4" NPT-F)
VI
VENTILATION DUCT CONN. (LOAD END) 4" x 16" ID
V2
VENTILATION DUCT CONN. (UNLOAD END) 4" x 16" ID
RA
SAN
S*
4 3 8 in
C*
V2
11 in
4 in
SAN
DET
S*
14 1 2 in
10 1 8 in (NOTE 3)
(NOTE 4)
07610-003-78-18-N