Timing Chart For Reading Starting System - HIOS CLT-AY-61 Operation Manual

Transformer with automatic controlled systems for electric screwdrivers
Table of Contents

Advertisement

Description
T1: 2 seconds or more of interval between ON and OFF of Main Switch must be kept.
T2: The power ON is reset when power is on. Even STARTING signal is on, the Transformer will
start at the primal condition.
T3: This signal combines the starting and stopping signal s of driver.
During the input of this signal, the driver rotates. However, in case that the torque is up, the
rotation will stop and the FINISH Signal is output wile this T3 signal is input (Monitoring of
signal is possible with the FUNCTION LED.)
T4: The rotation of driver is indicated. (Monitoring of signal is possible with the FUNCTION
LED.)
T5: This chart indicates that driver was stopped by RESET signal.
T6: This signal is output to the Transformer from driver when from driver when the torque of
driver reaches the fixed value.
(Monitoring of input signal is possible with the FUNCTION LED.)
T7. The timing is changed as the dotted lines by the fixed value of torque up Counter.
T8: This signal is output when the torque of driver reaches the fixed value and screwing is
completed. (Monitoring of input signal is possible with the FUNCTION LED.)
T9: Input of this RESET Signal is able to stop the rotation of driver at any time even external
operation. (Monitoring is possible with the FUNCTION LED.)

Timing Chart for Reading starting system