HIOS CLT-AY-61 Operation Manual

Transformer with automatic controlled systems for electric screwdrivers

Advertisement

Quick Links

Transformer with Automatic
Controlled Systems
For Electric Screwdrivers
Operation Manual
CLT-AY-61, CLT-AY-81
(March. 2017)
1-16-5 Akiyama, Matsudo City, Chiba Pref., Japan
Phone: +81-47-392-2001
FAX:
+81 47 392 7773
HIOS Inc.
Operation Manual No. ET-A035
17A

Advertisement

Table of Contents
loading

Summary of Contents for HIOS CLT-AY-61

  • Page 1 Transformer with Automatic Controlled Systems For Electric Screwdrivers Operation Manual CLT-AY-61, CLT-AY-81 (March. 2017) HIOS Inc. 1-16-5 Akiyama, Matsudo City, Chiba Pref., Japan Phone: +81-47-392-2001 FAX: +81 47 392 7773 Operation Manual No. ET-A035...
  • Page 2: Table Of Contents

    Thank you very much for your purchase the Transformer Model: CLT-AY-61, CLT-AY-81. Before starting the operation, read this manual to use CLT-AY-61and CLT-AY-81 safely and properly. This manual should be kept and read always. If in case of trouble, confirm the phenomenon’s by This manual and contact us soon.
  • Page 3: Cautions In Operation

    And confirmed the safety of all systems. All setting must be same before and after replacement. *Use this transformer only for control the designated automatic driver manufactured by HIOS. Note: Never use this for the manual drivers. It may cause trouble.
  • Page 4: Name Of Each Part

    Name of Each Part ● Front Panel (CLT-AY-81 is similar to CLT-AY-61) Main Switch: ON and OFF AC100, 120V or 220 - 240V Power with is brought to Transformer. Function Leeds: START : This lamp turns on while the START signal is input.
  • Page 5 ● Rear Panel (Terminal location of CLY-AY-81 is different from CLT-AY-61 but same function) Terminal :Connect Input and/or Output cables. Terminal is removable by unscrewing 2 screws at the both end of the terminal. When you do it, unscrew each of screw little by little.
  • Page 6: Setting Of Switches On The Pcb

    SW101 is placed toward Rear Panel side (P)--Pulse Input Starting toward Rear Panel side (R)--Reading Starting SW102: You can use both types (H type, or N type) of automatic driver manufactured by HIOS. The delivery time setting is for H type.
  • Page 7: Input And Output Circuit

    Input and Output circuit...
  • Page 8: Timing Chart For Pulse Input Starting System

    Timing Chart for Pulse input starting system Description T1: 2 seconds or more of interval between ON and OFF of Main Switch must be kept. T2: The proper input time of STARTING signal should be 10 msec to 50 msec. (You can monitor the input time with the FUNCTION LED.) T3: The rotation of driver is indicated.
  • Page 9: Timing Chart For Reading Starting System

    Timing Chart for Reading starting system Description T1: 2 seconds or more of interval between ON and OFF of Main Switch must be kept. T2: The power ON is reset when power is on. Even STARTING signal is on, the Transformer will start at the primal condition.
  • Page 10: Timing Chart Of Option: Rev Starting System

    Timing Chart of Option REV Starting System ● ●Timing Chart of Option 2WV Starting System...
  • Page 11: Notice Of Using Transformer For Multiple Axes

    Notice of using Transformer for Multiple Axes 1. Whenever the multiple axes driver is controlled, each of CLT-AY-61/81 Transformer should be used individually in each sequencer or system side. Simultaneous starting operation or AND execution of FINISH signal should be controller at each sequencer or system side.
  • Page 12: Power Supply For Automatic Screwdriver: Specification

    ■ Power supply for Automatic screwdriver CLT-AY-61 option: 2WV, REV or 2WV+REV Option CLT-AY-81 CLT-AY-61 CLT-AY-81 ●Specifications...
  • Page 13: Dimension

    2. Input system: Open collector Input (Low active) or Voltage input (High active). 3. Screw driver : Hios-product(HH/XH) or Nittoh Seikou-product(HH/XN) are applicable Each selection or adjustment is changeable even after purchase. (See the instructions) 5. Monitoring Input/Output function is possible with the function LED on the front panel.
  • Page 14: China Rohs2 Table

    China RoHS2 Table If you export to China by yourselves, below is the table of China RoHS2 In addition, if the following mark cannot be found at the rear side of the product and/or Product box, cut off a mark and stick a mark to the product and/or product box. Note: minimum size of China RoHS mark is 5mm at outer diameter...