Thank you very much for your purchase the Transformer Model: CLT-AY-61, CLT-AY-81. Before starting the operation, read this manual to use CLT-AY-61and CLT-AY-81 safely and properly. This manual should be kept and read always. If in case of trouble, confirm the phenomenon’s by This manual and contact us soon.
And confirmed the safety of all systems. All setting must be same before and after replacement. *Use this transformer only for control the designated automatic driver manufactured by HIOS. Note: Never use this for the manual drivers. It may cause trouble.
Name of Each Part ● Front Panel (CLT-AY-81 is similar to CLT-AY-61) Main Switch: ON and OFF AC100, 120V or 220 - 240V Power with is brought to Transformer. Function Leeds: START : This lamp turns on while the START signal is input.
Page 5
● Rear Panel (Terminal location of CLY-AY-81 is different from CLT-AY-61 but same function) Terminal :Connect Input and/or Output cables. Terminal is removable by unscrewing 2 screws at the both end of the terminal. When you do it, unscrew each of screw little by little.
SW101 is placed toward Rear Panel side (P)--Pulse Input Starting toward Rear Panel side (R)--Reading Starting SW102: You can use both types (H type, or N type) of automatic driver manufactured by HIOS. The delivery time setting is for H type.
Timing Chart for Pulse input starting system Description T1: 2 seconds or more of interval between ON and OFF of Main Switch must be kept. T2: The proper input time of STARTING signal should be 10 msec to 50 msec. (You can monitor the input time with the FUNCTION LED.) T3: The rotation of driver is indicated.
Timing Chart for Reading starting system Description T1: 2 seconds or more of interval between ON and OFF of Main Switch must be kept. T2: The power ON is reset when power is on. Even STARTING signal is on, the Transformer will start at the primal condition.
Notice of using Transformer for Multiple Axes 1. Whenever the multiple axes driver is controlled, each of CLT-AY-61/81 Transformer should be used individually in each sequencer or system side. Simultaneous starting operation or AND execution of FINISH signal should be controller at each sequencer or system side.
2. Input system: Open collector Input (Low active) or Voltage input (High active). 3. Screw driver : Hios-product(HH/XH) or Nittoh Seikou-product(HH/XN) are applicable Each selection or adjustment is changeable even after purchase. (See the instructions) 5. Monitoring Input/Output function is possible with the function LED on the front panel.
China RoHS2 Table If you export to China by yourselves, below is the table of China RoHS2 In addition, if the following mark cannot be found at the rear side of the product and/or Product box, cut off a mark and stick a mark to the product and/or product box. Note: minimum size of China RoHS mark is 5mm at outer diameter...