If a furniture unit is
installed at a distance of
400 mm above the hob,
there must be a
minimum safety distance
of 50 mm to the left or
right from the edge of
the hob.
5.
6.
A) supplied bracket
7.
CAUTION!
Install the appliance only on
a worktop with flat surface.
8.8 Installing hob under the
hood
If you install the hob under a
hood, please see the
installation instructions of
the hood for the minimum
distance between the
appliances.
A

8.9 Possibilities for insertion

The panel installed below the hob must
be easy to remove and let an easy access
in case a technical assistance
intervention is necessary.
Kitchen unit with door
B
min 20 mm
(max 150 mm)
60 mm
A. Removable panel
B. Space for connections
Kitchen unit with oven
The electrical connection of the hob and
the oven must be installed separately for
safety reasons and to let easy remove
oven from the unit.
ENGLISH
15
min 6 mm
A
min 40 mm