7 Troubleshooting

7
Troubleshooting
If one of the following malfunctions occur, take the measures shown
below and contact your dealer.
WARNING
Stop operation and shut off the power if anything
unusual occurs (burning smells etc.).
Leaving the unit running under such circumstances may
cause breakage, electric shock or fire. Contact your dealer.
The system must be repaired by a qualified service person:
Malfunction
If a safety device such as a fuse, a
breaker or an earth leakage breaker
frequently actuates or the ON/OFF
switch does not properly work.
If water leaks from the unit.
The operation switch does not work
well.
If the user interface display indicates the
unit number, the operation lamp flashes
and the malfunction code appears.
If the system does not properly operate except for the above
mentioned cases and none of the above mentioned malfunctions is
evident, investigate the system according to the following
procedures.
Malfunction
If the system does not
▪ Check if there is no power failure. Wait
operate at all.
until power is restored. If power failure
occurs during operation, the system
automatically restarts immediately after
the power supply is recovered.
▪ Check if no fuse has blown or breaker
has worked. Change the fuse or reset the
breaker if necessary.
The system stops
▪ Check if air inlet or outlet of outdoor or
immediately after
indoor unit is not blocked by obstacles.
starting operation.
Remove any obstacle and make it well-
ventilated.
▪ Check if the air filter is clogged. Contact
your dealer to clean the air filter.
Operation manual
6
Measure
Turn off the main power
switch.
Stop the operation.
Turn off the power.
Notify your installer and
report the malfunction
code.
Measure
Malfunction
The system operates
▪ Check if air inlet or outlet of outdoor or
but cooling or heating
indoor unit is not blocked by obstacles.
is insufficient.
Remove any obstacle and make it well-
ventilated.
▪ Check if the air filter is clogged. Contact
your dealer to clean the air filter (refer to
"Maintenance" in the indoor unit manual).
▪ Check the temperature setting. Refer to
the manual of the remote controller.
▪ Check the fan speed setting is set to low
speed. Refer to the manual of the remote
controller.
▪ Check if the air flow angle is proper.
Refer to the manual of the remote
controller.
▪ Check for open doors or windows. Shut
doors and windows to prevent wind from
coming in.
▪ Check if direct sunlight enters the room.
Use curtains or blinds.
▪ Check if there are too many occupants in
the room during cooling operation. Check
if the heat source of the room is
excessive.
▪ If the heat source of the room is
excessive (when cooling). Cooling effect
decreases if heat gain of the room is too
large.
If after checking all above items, it is impossible to fix the problem
yourself, contact your installer and state the symptoms, the complete
model name of the unit (with manufacturing number if possible) and
the installation date (possibly listed on the warranty card).
7.1
Symptoms that are NOT system
malfunctions
The following symptoms are NOT system malfunctions:
7.1.1

Symptom: The system does not operate

▪ The air conditioner does not start immediately after the ON/OFF
button on the remote controller is pressed. If the operation lamp
lights, the air conditioner is in normal condition. It does not restart
immediately because one of its safety devices actuates to prevent
the air conditioner from being overloaded. The air conditioner will
turn on again automatically after 3 minutes.
▪ The air conditioner does not start immediately after the power
supply is turned on. Wait 1  minute until the micro computer is
prepared for operation.
▪ The air conditioner does not restart immediately when the
temperature setting button is returned to its former position after
pushing. It does not restart immediately because one of its safety
devices actuates to prevent the air conditioner from being
overloaded. The air conditioner will turn on again automatically
after 3 minutes.
▪ The outdoor unit has stopped. This is because the room
temperature has reached the set temperature. The unit switches
to fan operation. "
" (external control icon) is displayed on
the remote controller and the actual operation is different from the
remote controller setting. For multi split models, the micro
computer executes the following control depending on the
operation mode of other indoor units.