ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR 8 pieces 2 pieces OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE Insulation for Long sealing fitting 2 pieces SPECIFICALLY DESIGNED FOR USE WITH THE EQUIPMENT AND HAVE THEM INSTALLED BY A PROFESSIONAL.
For the following items, take special care during • Do not place objects that are susceptible to moisture directly beneath the indoor or outdoor units. Under certain conditions, construction and check after installation is finished condensation on the main unit or refrigerant pipes, air filter dirt or drain blockage may cause dripping, resulting in fouling Tick ...
NOTE When attaching a duct to the intake side, be sure to attach your Daikin dealer for details. an air filter inside the air passage on the intake side. (Use an air filter whose dust collecting efficiency is at least 50% The fan speed for this indoor unit is preset to provide standard in a gravimetric technique.)
Make sure there is no refrigerant gas leak. A toxic gas may be Be sure to insulate the duct to prevent condensation released by the refrigerant gas leaking indoor and being from forming. (Material: glass wool or polyethylene exposed to flames from an area heater, cooking stove, etc. foam, 25 mm thick) Finally, insulate as shown in the figures below.
Drain piping work After piping work is finished, check drainage flows smoothly. • Gradually insert approximately 1L of water into the drain pan Installation of drain piping to check drainage in the manner described below. Install the drain piping as shown in the figure and take measures •...
Electric wiring work Wiring example and how to set the remote controller General instructions How to connect wiring All field wiring and components must be installed by a licensed electrician and must comply with relevant European and national Remove the switch box cover as shown in figure 10, and make the regulations.
Use only specified wires and tightly connect wires to the terminals. When controlling the simultaneous operation system with Be careful that wires do not place external stress on the terminals. 2 remote controllers, connect it to the master unit (wiring to the Keep wiring in neat order so that they do not obstruct other slave unit is unnecessary).
Setting air filter sign When the air conditioning unit has stopped, check on an indoor unit if the second code No. of mode No. 21 is set to "02". Remote controllers are equipped with liquid crystal air filter signs If the air conditioning unit does not stop operating or the second to display the time to clean the air filter.
Wiring diagram Unified Wiring Diagram Legend For applied parts and numbering refer to the wiring diagram sticker supplied on the unit. Part numbering is realized by Arabic numbers in ascending order for each part and is represented in the overview below by symbol “*” in the part code. CIRCUIT BREAKER PROTECTIVE EARTH CONNECTION...
Page 15
1 2 3 P1 P2 F1 F2 T1 T2 Sec A A’ A’ A’ 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 L N 1 2 3 L N 1 2 3 L N 1 2 3 1 2 3 1 2 3...