Panasonic CS-E9GFEW Operating Instructions Manual page 2

Hide thumbs Also See for CS-E9GFEW:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Thank you for purchasing Panasonic Air Conditioner.
Installation instructions attached.
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
The illustrations in this manual are for explanation purposes only and may differ from the actual unit.
They are subject to change without notice for future improvement.
Multi air conditioner system
Multi air conditioner systems save space by
letting you connect multiple indoor units to a
single outdoor unit.
• For complete product features, please refer
catalogue.
Indoor units
• It is possible to operate the indoor units
individually or simultaneously. The priority
of operation is placed on the fi rst unit that
turned on.
• During operation, HEAT and COOL modes
cannot activate at the same time for different
indoor units.
• The power indicator blinks to indicate the
indoor unit is standing by for a different
operation mode.
Operation conditions
Use this air conditioner under the following temperature range.
DBT: Dry bulb temperature / WBT: Wet bulb temperature
Single split outdoor unit
CU-E9PFE, CU-E12PFE, CU-E18PFE
COOL
HEAT
Multi split outdoor unit
CU-2E15PBE, CU-2E18PBE,
CU-3E18PBE, CU-4E23PBE,
CU-4E27PBE, CU-5E34PBE
COOL
HEAT
2
Indoor
DBT WBT DBT WBT
Max.
32
23
Min.
16
11
Max.
30
-
Min.
16
-
°C (temperature)
Indoor
DBT WBT DBT WBT
Max.
32
23
Min.
16
11
Max.
30
-
Min.
16
-
°C (temperature)
Outdoor unit
( CU-2E15PBE, CU-2E18PBE, CU-3E18PBE,
CU-4E23PBE, CU-4E27PBE, CU-5E34PBE)
Outdoor
43
26
16
11
24
18
-15
-6
Outdoor
46
26
-10
-
24
18
-15
-16
Indoor units

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents