Important Information Regarding The Refrigerant Used - Haier HSU-26HEK03/R2(DB)/I Operation Manual

Table of Contents

Advertisement

Important information regarding the refrigerant used

This product contains
greenhouse gases covered by the Kyoto
Protocol. Do not vent into the atmosphere.
Refrigerant type: R410A
GWP* value: 1975
GWP = global warming potential
Please
in with indelible ink,
1 the factory refrigerant charge of the product
2 the additional refrigerant amount charged in the
1+2 the total refrigerant charge on the refrigerant charge label supplied
with the product.
The
out label must be adhered in the proximity of the product charging port
(e.g. onto the inside of the stop value cover).
Emergency operation and test operation
Emergency Operation:
Use
this only when the remote controller is defective or lost. air conditioner can
run automatically for a short time.
When the emergency operation switch is pressed, the "Pi" sound is heard once,
which means emergency operation has started.
When power switch is turned on for the
starts, the unit will run automatically in the following modes:
Room
Timer
Designated
temperature
mode
temperature
o
o
Above 23
C
26
C
No
o
o
Below 23
C
23
C
No
It is impossible to change the settings of temperature fan speed, or to operate in
timer or dry mode.
and
time and emergency operation
emergency
Fan
Operation
operation switch
speed
mode
AUTO
COOL
AUTO
HEAT
Contains fluorinated greenhouse gases
covered by the Kyoto Protocol
R410A
1=
2
2=
1
1+2=
F
E
A contains
greenhouse gases covered by the Kyoto Protocol
B factory refrigerant charge of the product: see unit name plate
C additional refrigerant amount charged in the
D total refrigerant charge
E outdoor unit
F refrigerant cylinder and manifold for charging
Test operation:
The test operation switch is the same as the emergency switch.
Use this switch in the test operation when
the room temperature is below 16°C.
Do not use it during normal operation.
Continue to press the test operation switch
for more than 5 seconds . After you hear the
"Pi" sound twice, release your
the switch: the cooling operation starts with
the air
speed "Hi".
Under this operation mode, the fan motor of indoor unit will run in high speed.
A
kg
B
kg
C
kg
D
test operation
from
switch
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hsu-35hek03/r2(db)/iHsu-53hek03/r2(db)/iHsu-71hek03/r2(db)/i

Table of Contents