Toyotomi Zibro LC-130 Operating Manual page 9

Hide thumbs Also See for Zibro LC-130:
Table of Contents

Advertisement

!
setting, which you can use when, for instance, you are not present in the room
K
THE 'FUEL' INDICATOR
information display ¸
¼ you remove the fuel tank and refill it outside the living room (section B)
two minutes, warning you to refill the removable tank. If you do not react,
the heater will extinguish by itself. The heater will also sound a warning
signal, when it switches off. The fuel indicator will blink, while four lines
button ¹ once more.
the
Once the heater has used up all its fuel and extinguished, it will take some time,
after the refill, before the heater is completely ready for use again.
L
THE 'VENT' INDICATOR
continues blinking after extra ventilation, please contact your dealer.
M
MAINTENANCE
Switch off the heater and let it cool down, before you start any maintenance
maintenance. It is, however, important that you clean the vent filter
vacuum cleaner and the grid
Regularly inspect the fuel filter as well:
1 Remove the removable tank
2
(Never clean it with water!)
3 Reinstall the fuel filter into the heater.
We recommend that you remove dust and stains from time to time with a damp
cloth, because otherwise these may cause stains that are hard to remove.
with a damp cloth, both on a weekly basis.
from the heater and remove the fuel filter
J: When the FUEL
indicator has appeard,
the information display
will show the number of
minutes of fuel left in
the tank.
K: A blinking VENT
indicator is a sign
that you need extra
ventilation.
with a
Fuel filter
9
L

Hide quick links:

Advertisement

Table of Contents
loading