Bus Address - Keithley 707A Instruction Manual

Table of Contents

Advertisement

Operation
Table
4-1
Status
of
slave
unit controls
Control,
indicator,
or
connector
Status
POWER
active
CROSSPOINT
DISPLAY
Group:
MEMORY
key
and
LED
only
LED
active
RELAYS
key and
LED
only
LED
active
CROSSPOINT
DISPLAY
active
MODIFIED LED
COPY
DISPLAY
MEMORY
inactive
COPY
DISPLAY
RELAYS
inactive
AUTOMATIC
key and
LED
only
LED
active
SCROLL
A
and
SCROLL
y
inactive
MEMORY
Group:
INSERT
inactive
DELETE
inactive
menu
key and
LED
inactive
SWITCHING
Group:
SETfLINGTIME
inactive
MAKE/BREAK
inactive
BREAK/MAKE
inactive
LOCAL
inactive
TRIGGER
Group;
ENABLE
key
and
LED
only
LED
active
source
inactive
MANUAL
inactive
Data
Entry
(A-H,
0-9)
inactive
cancel,
enter
inactive
RESET
inactive
clear, open,
CLOSE
inactive
Alphanumeric
Display
active
(Note
1)
TALK,
LISTEN,
REMOTE
LEDs
inactive
Crosspoint Display
LEDs
active
MAKE/BREAK
and
BREAK/MAKE
active
Row LEDs
LIGHT PEN
inactive
Rear
Panel Connectors:
MASTER/SLAVE
IN
active
MASTER/SLAVE
OUT
active
EXTERNAL
TRIGGER
INPUT
inactive
MATRIX
READY OUTPUT
active
(Note
2)
REALY
TEST
not
used
DIGITAL
I/O
inactive
(Note
3)
IEEE-488
INTERFACE
not
used
Notes:
1
.
Messages
only.
2.
Timing
accuracy
not guaranteed.
3.
Outputs
set to
all
low.
4.9.5
IEEE-488
bus
address
The Model
707A
communicates
over
the
IEEE-488 bus
through
the
rear panel
connection
shown
in
Figure 4-13.
When
connected
to
a bus
controller,
instrument operating
modes
can
be
programmed. Note
that
IEEE-488
common
is
always grounded.
IEEE-488
interface
function
codes
are
marked
adjacent
to
the connector.
(fS
(T^
SHI
AH1
T6
TEO
L4
LEO
SRI
BL1
PRO
DC1
DTI
El
CO
Figure 4-13
IEEE-488
bus connector
A
menu
item
is
used
to set
the
primary
address of
the
Model
707A
for
bus
operation.
The
primary
address of
the
Model
707
A
is
factory set
to 18,
but
it
may
be
set to
any
value
between 0 and 30
as
long
as
address
conflicts
with other
instruments or
the
bus
controller are
avoided.
To
check
the
present
primary
address or
to
change
to
a
new
one,
perform
the
following procedure:
1
.
Press
the
MENU
key
until
the current
primary address
is
displayed.
For example,
if
the
instrument
is
set
to pri-
mary
address
18, the
following
message
is
displayed:
IEEE-488
18
2.
Press
CANCEL
to
retain the
present address
and
exit
menu
mode.
3.
To
change
the
primary
address,
use
the
data entry
keys
to
key
in
a
new
value,
then
press
ENTER.
This action
will also exit
menu
mode.
The new
address
will
be
stored
in
memory
so
that the
instrument
powers up
to
that
address.
4-17

Advertisement