Page 9
(5) As to wire size of main circuit wiring, see [Input/Output devices and wiring] of Chapter 4, item 2. (6) In case that shielded wire is used for output wiring or wiring length is over 300m and when ED64sp Inverter is operated by its DC excitation function, there may be a case that Inverter is broken or it does not work normally caused by leaka- gecapacitance to earth of output wiring of Inverter and resonance phenomenon of input power source inductance.
Page 61
Even if torque command is constant, output torque lowers, Even in constant output area, output torque is constant if being inversely proportional to the speed, in order to make command is constant. (Torque limiter lowers for making the output constant in the constant output area. the constant output.)
Page 80
Function to confirm internal data of Inverter by analog or console display, by setting of internal address of CPU. (This function is for our test and for special application. Keep initial values ordinary).
Page 117
HEAD OFFICE: Tokyo Tatemono Yaesu Bldg, 1-4-16 Yaesu, Chuo-ku, Tokyo, Japan ZIP CODE 103-0028 TEL: +81-3-5202-8132 - 6 FAX: +81-3-5202-8150 Contents of this manual are subject to change without notice. 2012-09 ITE050B...