When checking the DIGITAL (1) P.C.B.:
Put the rubber sheet and cloth over this unit, and place the DIGITAL (1) P.C.B. on them. (Fig. 5)
Connect ST951 on DIGITAL (1) P.C.B. to the chassis with a ground lead. (Fig. 5)
Reconnect all cables (connectors) that have been disconnected. Be sure to use the P.C.B. CHECKING JIG (Part No.
ZF454800) to connect between the following connectors.
CB945 on DIGITAL (1) P.C.B. – CB381 on OPERATION (4) P.C.B.
When connecting the flexible flat cable, be careful with polarity.
Rubber sheet and cloth
20
DIGITAL (1) P.C.B.
ST951
Ground lead
Fig. 5
CB945
P.C.B. CHECKING JIG
OPERATION (4) P.C.B.
CB381
Chassis