RX-V675/HTR-6066/RX-A730/TSR-6750
When checking the DIGITAL (1) P.C.B.:
•
Put the rubber sheet and cloth over this unit, and place the DIGITAL (1) P.C.B. on them. (Fig. 5)
•
Connect ST951 on DIGITAL (1) P.C.B. to the chassis with a ground lead. (Fig. 5)
•
Reconnect all cables (connectors) that have been disconnected. Be sure to use the P.C.B. CHECKING JIG (Part No.
ZF454800) to connect between the following connectors.
CB945 on DIGITAL (1) P.C.B. – CB381 on OPERATION (4) P.C.B.
•
When connecting the flexible flat cable, be careful with polarity.
Rubber sheet and cloth
20
DIGITAL (1) P.C.B.
ST951
Ground lead
Fig. 5
CB945
P.C.B. CHECKING JIG
OPERATION (4) P.C.B.
CB381
Chassis