Mass Electronics Pty Ltd. Trademark The term ‘Innotech’ used in this manual is a trademark of Mass Electronics Pty Ltd trading as Innotech Control Systems Australia. 'Microsoft', 'Windows' and 'Internet Explorer' are registered trademarks of Microsoft Corporation in the United States and other countries.
Installation Instructions for Innotech IG04 BACnet Gateway and Vaisala Transmitter / Sensor Overview This document provides instructions to connect a Vaisala device to the IG04 BACnet Gateway, and configuring the Vaisala device and IG04 using the embedded web server and the FusionLIVE Java application.
Installation Instructions for Innotech IG04 BACnet Gateway and Vaisala Transmitter / Sensor Wiring Using The 8-Pin M12 Connector With Independent Cabling For Heating The wiring example provided below at Figure 1 is recommended for most installations, providing a separate cabling run of high quality cable for the Vaisala device heating current (if required). The pin...
Installation Instructions for Innotech IG04 BACnet Gateway and Vaisala Transmitter / Sensor Wiring Using The 8-Pin M12 Connector With Split Cabling For Heating The wiring example provided below at Figure 2 is an alternative M12 connector wiring guide, providing a shared cabling run of suitable high capacity cable for the Vaisala device and heating accessory (if required).
Installation Instructions for Innotech IG04 BACnet Gateway and Vaisala Transmitter / Sensor Vaisala Device 8-Pin M12 Connector Pin-Outs Please take extreme care to ensure when installing and wiring that the wire colours and terminals correctly match as illustrated in Figure 1 or Figure 2, and described below in Table 1. Refer to the appropriate Vaisala technical documentation for more details at www.vaisala.com.
Installation Instructions for Innotech IG04 BACnet Gateway and Vaisala Transmitter / Sensor Wiring Using The Screw Terminal Connector With Independent Cabling For Heating The wiring example provided below at Figure 3 is recommended for most installations, providing a separate cabling run of high quality cable for the heating current (if required). The pin connections for...
Installation Instructions for Innotech IG04 BACnet Gateway and Vaisala Transmitter / Sensor Wiring Using The Screw Terminal Connector With Split Cabling For Heating The wiring example provided below at Figure 4 is an alternative screw terminal wiring guide, providing a shared cabling run of suitable high capacity cable for the Vaisala device and heating accessory (if required).
Installation Instructions for Innotech IG04 BACnet Gateway and Vaisala Transmitter / Sensor Vaisala Device Screw Terminal Pin-Outs Please take extreme care to ensure when installing and wiring that the wire colours and terminals correctly match as illustrated in Figure 1 Figure 2, and described below in Table 2.
Installation Instructions for Innotech IG04 BACnet Gateway and Vaisala Transmitter / Sensor Accessing Embedded Web Server and FusionLIVE The Vaisala device and IG04 BACnet Gateway can be configured using the embedded web server and the FusionLIVE Java application on the IG04. However before you can access the embedded web server, your computer must be configured to be on the same network range as the IG04 BACnet Gateway.
IG04 BACnet Gateway and Vaisala device has been properly configured. The embedded web server's home page for the Vaisala WXT Weather Transmitter is illustrated in Figure 7 below, while the home page for the Vaisala WMT Ultrasonic Wind Sensor can be seen at Figure 8.
Installation Instructions for Innotech IG04 BACnet Gateway and Vaisala Transmitter / Sensor Animated Graphics on the Home Page The home page provides animated graphical representations of live weather conditions when connected to a Vaisala Weather Transmitter. The range of graphics and their meanings are illustrated in below in Figure 9.
Page 14
Installation Instructions for Innotech IG04 BACnet Gateway and Vaisala Transmitter / Sensor When the button on the home page is clicked, the FusionLIVE window will be displayed. Refer to the illustration and table below for more detailed information. Actual live data in FusionLIVE will not be present until the connection between the IG04 BACnet Gateway and Vaisala device has been properly configured.
Installation Instructions for Innotech IG04 BACnet Gateway and Vaisala Transmitter / Sensor Configuring Vaisala Device with FusionLIVE When you have accessed the FusionLIVE Java application as described in the Accessing Embedded Server and FusionLIVE section, you can modify the configuration settings of the Vaisala device by clicking on the button from the FusionLIVE window.
There is no password configured by default, but if a password is configured then you can only view the data; you cannot make any changes. In cases where you forget the configured password, you will need to contact Innotech to reset your password. Contact details are shown on the last page of this document.
Installation Instructions for Innotech IG04 BACnet Gateway and Vaisala Transmitter / Sensor BACnet Tab Under the BACnet tab you can configure or modify the following settings: • BACnet Instance number • BACnet Datalink protocol • BACnet MS/TP Settings Please note that the MS/TP settings can only be modified if the BACnet Datalink is selected as MSTP.
Installation Instructions for Innotech IG04 BACnet Gateway and Vaisala Transmitter / Sensor Clock Tab Under the Clock tab you can configure or modify the following settings: • Current date and time – used for the Precipitation Reset setting • Daylight Savings time • Location –...
Installation Instructions for Innotech IG04 BACnet Gateway and Vaisala Transmitter / Sensor Configuring Sunrise and Sunset If you enable the Sunrise / Sunset feature of the IG04, you will need to enter the latitude and longitude coordinates to determine the sunrise and sunset for your particular location. This information can be obtained from http://www.findlatitudeandlongitude.com, using the map to find...
Installation Instructions for Innotech IG04 BACnet Gateway and Vaisala Transmitter / Sensor Ethernet Tab Under the Ethernet tab you can configure or modify the following settings: • Address type, IP address, Default Router, and Net Mask • HTTP Port Number • Net Comms Port number (Innotech Service Port number) • BACnet Port number...
• Reboot Gateway Now – Reboot the IG04 BACnet Gateway The Maintenance mode is a service tool for Innotech personnel only. It MUST be set to Normal in order to view the data from the Vaisala device, unless instructed otherwise, as illustrated in Figure 19 below.
Installation Instructions for Innotech IG04 BACnet Gateway and Vaisala Transmitter / Sensor Troubleshooting The most common issues when connecting to the IG04 BACnet Gateway's embedded web server and FusionLIVE are incorrect proxy settings or inappropriate security levels in Internet Explorer. If you are experiencing a problem that cannot be resolved, try some of the steps outlined below.
Installation Instructions for Innotech IG04 BACnet Gateway and Vaisala Transmitter / Sensor Cannot Launch FusionLIVE • When first launching FusionLIVE from the IG04 BACnet Gateway's embedded web server, you may encounter a window that asks you to install the Java Runtime Environment (JRE). Ensure to follow the prompts to download the JRE from the internet.
Installation Instructions for Innotech IG04 BACnet Gateway and Vaisala Transmitter / Sensor Innotech Support Innotech provides technical information on the Web to assist you with using its products. At www.innotech.com.au, you can find technical manuals, user instructions, and data sheets for all our products.
Need help?
Do you have a question about the Vaisala WXT and is the answer not in the manual?
Questions and answers