(8) LP-E5092HL/ZL/HA/ZA
INDOOR ELECTRIC CIRCUIT
Outdoor Unit Wiring Diagram
WH
TM
R S T N
3ø, 3 wires,
WH
220V.
3ø, 4 wires,
380V.
Co
YL
BR
BK
FMo1
49FMo
( Caution )
1. Basic wiring is 3ø,4 wires, 380V.
2. For changing the running
voltage to 220V, please change
the wiring by the next steps.
1st) Remove the 2 wires from
the "N" of the main terminal
block
2nd) Fit the removed 2 wires
on the "S' of the main
terminal block
3rd) Change the compressor
wires
BK
63H2
BK
a
OR
b
BK
WH
RD
BK
52C
1
3
5 31
A
B
2
4
6 32
BK
RD
BK
51C
Co
Ta
Tc
L1 L2
BK WH
RD
OR
YL
OR
BR
WH
BK
WH
FMo2
WH RD
BK
V W X
49FMo
U
Y
20SV
Z
CM
V
Y
U W
X Z
3ø,4 wires,380V.
3ø,3 wires,220V.
C TH
D.P
TNS
NO
NC
WH
52F1
BK
1
2
3
4
T/B1
5
6
WH
7
8
YL
T/B2
WH
WH
RD
BK
BK
BR
1
BL
2
BR
3
BL
BL
4
5
GN/YL
6
BL
Tmo
GN/YL
3. For setting E.O.C.R current
POWER SUPPLY
V
Y
3ø,220V,60HZ
U W
X Z
3ø,380V,60HZ
– 17 –
NOTE
:
:
BL
BLUE
RD
RED
:
:
BK
BLACK
WH
WHITE
BR
:
BROWN
YL
:
YELLOW
OR
:
ORANGE
GN/YL
:
GREEN/YELLOW
63H2
HIGH PRESSURE SWITCH FOR HEATING
C TH
THERMISTOR FOR PIPE TEMP.
63H1
INTERNAL T.P FOR FMo
CH
CRANKCASE HEATER
20SV
REVERSING COIL
MAGNETIC CONTACTOR
52C
TM
MAIN TERMINAL BLOCK
RELAY FOR FMO
52F1
E.O.C.R
51C
CM
COMPRESSOR
RUN CAPACITOR FOR FMo
Co
FMo
OUTDOOR FAN MOTOR
FUSE (250V, 10A)
F1
DP
DEICER PCB
TMo
TERMINAL BLOCK
CURRENT(A)
TIME(sec)
30.0
5
17.5
5
WIRING FOR 380V
WIRING FOR 220V
WIRING OF FIELD
(CONNECTING WIRE)