Mitsubishi MXZ-4C36NAHZ Technical & Service Manual page 20

Split-type, heat pump air conditioners
Table of Contents

Advertisement

4-2. CORRECTING BY TEMPERATURE
MXZ-4C36/5C42/8C48NA(HZ), 8C60NA could have varied capacity at different designing temperature. Using the nominal
cooling/heating capacity value and the ratio below, the capacity can be observed at various temperature.
<Cooling>
4C36
BTU/h
36,000
Nominal cooling capacity
Input
kW
2.57
8C48
BTU/h
48,000
Nominal cooling capacity
Input
kW
4.00
Figure 8 Outdoor unit temperature correction
To be used to correct outdoor unit capacity only
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
5
14
-15
-10
1.2
1.0
0.8
0.6
0.4
0.2
0.0
5
14
-15
-10
OCH573C
Figure 7 Indoor unit temperature correction
To be used to correct indoor unit capacity only
MXZ
5C42
48,000
3.13
MXZ
8C60
60,000
4.80
23
32
41
50
-5
0
5
10
68.0°F (20.0°C) W.B.
68.0°F (20.0°C) W.B.
75.2°F (24.0°C) W.B.
75.2°F (24.0°C) W.B.
67.0°F (19.4°C) W.B.
67.0°F (19.4°C) W.B.
23
32
41
-5
0
5
1.2
1.0
0.8
0.6
0.4
59
60.8
62.6
64.4
15
16
17
18
Indoor Temperature
59
68
77
15
20
25
Outdoor Temperature
71.6°F (22.0°C) W.B.
71.6°F (22.0°C) W.B.
50
59
68
77
10
15
20
25
Outdoor Temperature
20
66.2
68
69.8
71.6
73.4
19
20
21
22
23
Indoor Temperature
67.0°F (19.4°C) W.B.
86
95
104
113
[°F W.B.]
[°C W.B.]
30
35
40
45
Indoor Temperature
64.4°F (18.0°C) W.B.
64.4°F (18.0°C) W.B.
60.8°F (16.0°C) W.B.
60.8°F (16.0°C) W.B.
86
95
104
113
30
35
40
45
75.2
[°FW.B.]
24
[°CW.B.]
[°F W.B.]
[°C W.B.]