8-7. HOW TO CHECK THE COMPONENTS
<Thermistor characteristic Graph>
Low temperature thermistors
• Thermistor <HIC pipe> (TH2)
• Thermistor <Outdoor liquid pipe> (TH3)
• Thermistor <Suction pipe> (TH6)
• Thermistor <Ambient> (TH7)
Thermistor R0 = 15 k" ± 3 %
B constant = 3480 ± 2 %
1
R
=15exp{3480(
t
273+t
273
32˚F [0:]
15 kΩ
50˚F [10:]
9.6 kΩ
68˚F [20:]
6.3 kΩ
77˚F [25:]
5.2 kΩ
Medium temperature thermistor
• Thermistor <Heat sink> (TH8)
Thermistor R50 = 17 k" ± 2 %
B constant = 4170 ± 3 %
1
R
=17exp{4170(
t
273+t
32˚F [0:]
180 k"
77˚F [25:]
50 k"
122˚F [50:]
17 k"
158˚F [70:]
8 k"
194˚F [90:]
4 k"
High temperature thermistor
• Thermistor <Compressor> (TH4)
Thermistor R120 = 7.465 k" ± 2 %
B constant = 4057 ± 2 %
1
R
=7.465exp{4057(
t
273+t
68˚F [20:]
250 kΩ
86˚F [30:]
160 kΩ
104˚F [40:]
104 kΩ
122˚F [50:]
70 kΩ
140˚F [60:]
48 kΩ
OCH573C
1
)}
86˚F [30:]
4.3 kΩ
104˚F [40:]
3.0 kΩ
1
)}
323
1
)}
393
158˚F [70:]
34 kΩ
176˚F [80:]
24 kΩ
194˚F [90:]
17.5 kΩ
212˚F [100:]
13.0 kΩ
230˚F [110:]
9.8 kΩ
50
40
30
20
10
0
−4 −14 32 50 68 86 104122 °F
−20 −10 0 10 20 30 40 50
Temperature
200
150
100
50
0
77
25
500
400
300
200
100
0
77
25
114
:
122
167 212 230 257 ºF
50
75
100 110 125 :
Temperature
122
167
212
248 ºF
50
75
100
120
:
Temperature