COMPONENT
SUCTION ELBOW
DISCHARGE ELBOW
CONTROL PANEL†
OPTIONAL COOLER INLET ISOLATION VALVE
OPTIONAL DISCHARGE ISOLATION VALVE
STD TIER VFD — 380, 400, AND 460-V
(230, 335, 445 A)
STD TIER VFD — 380, 400, AND 460-V (485, 550 A)
STD TIER VFD — 380, 400, AND 460-V (605, 680 A)
STD TIER VFD — 380, 400, AND 460-V (765 A)
STD TIER VFD — 380, 400, AND 460-V
(855, 960, 1070 A)
STD TIER VFD — 380, 400, AND 460-V (1275 A)
STD TIER VFD — 380, 400, AND 460-V (1530 A)
LIQUIFLO™ 2 VFD — 380, 400, AND 460-V (442 A)
LIQUIFLO 2 VFD — 380, 400, AND 460-V (608 A)
LIQUIFLO 2 VFD — 380, 400, AND 460-V (900 A)
LIQUIFLO 2 VFD — 380, 400, AND 460-V (1200 A)
LIQUIFLO 2 VFD — 575-V (390 A)
VFD SHELF
*To determine compressor frame size, refer to 19XR,XRV Com-
puter Selection Program.
†Included in total cooler weight.
Table 5A — 19XR Compressor and Motor Weights* — Compressor Frame Size 2†
MOTOR
COMPRESSOR
CODE
STATOR
WEIGHT**
WEIGHT††
(LB)
(LB)
STANDARD-EFFICIENCY MOTORS / LOW VOLTAGE (200-575 V)
BDS
2300
900
BES
2300
915
BFS
2300
975
BGS
2300
1000
BHS
2300
1030
BJS
2300
1105
HIGH-EFFICIENCY MOTORS / LOW VOLTAGE (200-575 V)
BDH
2300
1030
BEH
2300
1070
BFH
2300
1120
BGH
2300
1175
BHH
2300
1175
BJH
2300
1175
JBH
2300
1003
JCH
2300
1063
JDH
2300
1113
JEH
2300
1149
JFH
2300
1196
*Total compressor weight is the sum of the compressor aerody-
namic components (compressor weight column), stator, rotor, and
end bell cover weights.
†See Model Number Nomenclature in Fig. 2.
Table 4 — 19XR Component Weights
FRAME 2
COMPRESSOR*
LB
116
100
34
8
26
650
—
—
—
—
—
—
1600
—
—
—
2200
—
ENGLISH
60 HZ
50 HZ
ROTOR
STATOR
ROTOR
WEIGHT
WEIGHT††
WEIGHT
(LB)
(LB)
(LB)
190
915
205
200
965
220
215
1000
230
230
1060
250
240
1105
265
265
—
—
240
1030
240
250
1070
250
265
1120
265
290
1175
290
290
1175
290
290
—
—
226
1063
248
248
1113
263
263
1149
278
278
1196
295
295
—
—
FRAME 3
COMPRESSOR*
KG
LB
KG
53
185
84
45
125
57
15
34
15
4
13
6
12
46
21
295
650
295
—
1035
469
—
1600
726
—
—
—
—
—
—
—
—
—
—
—
—
726
1600
726
—
1600
726
—
—
—
—
—
—
998
2200
998
—
—
—
NOTE: VFD sizes are available on select heat exchanger models;
consult the 19XR,XRV Computer Selection program.
END
BELL
COMPRESSOR
STATOR
COVER
WEIGHT**
WEIGHT††
WEIGHT
(KG)
(KG)
(LB)
185
1043
408
185
1043
415
185
1043
442
185
1043
454
185
1043
467
185
1043
501
185
1043
467
185
1043
485
185
1043
508
185
1043
533
185
1043
533
185
1043
533
185
1043
455
185
1043
482
185
1043
505
185
1043
521
185
1043
542
**Compressor aerodynamic component weight only, motor weight
not included. Applicable to standard compressors only. For high lift
compressors, contact Carrier Chiller Marketing for weights.
††Stator weight includes the stator and shell.
10
FRAME 4
FRAME 5
COMPRESSOR*
COMPRESSOR*
LB
KG
LB
239
108
407
157
71
325
34
15
34
20
9
24
74
34
108
—
—
—
1035
469
—
1600
726
—
1600
726
—
1600
726
1600
3000
1361
3000
—
—
3000
—
—
—
1600
726
—
2800
1270
2800
2850
1293
2850
—
—
—
1049
476
1049
SI
60 HZ
50 HZ
ROTOR
STATOR
ROTOR
WEIGHT
WEIGHT††
WEIGHT
(KG)
(KG)
(KG)
86
415
93
91
438
100
98
454
104
104
481
113
109
501
120
120
—
—
109
467
109
113
485
113
120
508
120
132
533
132
132
533
132
132
—
—
103
482
112
112
505
119
119
521
126
126
542
134
134
—
—
KG
185
147
15
11
49
—
—
—
—
726
1361
1361
—
—
1270
1293
—
476
END
BELL
COVER
WEIGHT
(KG)
84
84
84
84
84
84
84
84
84
84
84
84
84
84
84
84
84