2. Funtion

Indoor Unit
Operation ON/OFF by Remote controller
Sensing the Room Temperature
Room temperature control
Starting Current Control
Time Delay Safety Control
Indoor Fan Speed Control
Soft Dry Operation Mode
• Although the air-conditioner is turned off by a power failure, it is restarted auto-
Auto Restart
Deice (defrost) control (Heating)
Hot-start Control (Heating)
High head height Drain pump
Central Control(Optional)
• Room temperature sensor. (Thermistor)
• Maintains the room temperature in accordance with the Setting Temperature.
• Indoor fan is delayed for 5 seconds at the starting.
• Restarting is inhibited for approx. 3 minutes.
• High, Med, Low
• Intermittent operation of fan at low speed.
matically previous operation mode after power supply.
• Both the indoor and outdoor fan stops during defrosting.
• Hot start after defrost ends.
• The indoor fan does not rotate until the evaporator piping
temperature reaches 25°C.
• A standard drain-head height of up to 700mm is possible.
• It is operating individually or totally by central control function.
Functions
Service Manual 61