D4 Valve
July 2015
8. Install the Belleville springs (key 11). The Belleville springs (key 11) should be single stacked with the I.D. of the
inner spring contacting the packing spacer (key 14) and the O.D. of the outer spring contacting the packing retainer
(key 10). The final Belleville spring should be within the 1.26 inch diameter bore of the bonnet.
9. Adjust the packing retainer by hand until it makes contact with the Belleville springs. Do not tighten by hand, simply
install the packing retainer until it makes contact with the Belleville springs. Tighten the packing retainer clockwise
precisely 1.16 turns (7 flats on the retainer) to seat the packing. This should fully compress the Belleville springs as
detected by an increase in torque between 6 and 7 flats.
10. Loosen the packing retainer completely. Adjust the packing retainer by hand until it makes contact with the
Belleville springs. Do not tighten by hand, simply install the packing retainer until it makes contact with the
Belleville springs. Tighten the packing retainer clockwise precisely 1/2 turn (3 flats on the retainer).
11. Lock the packing retainer (key 10) solidly in place by tightening the packing retainer locknut (key 22) using a
spanner wrench or a hammer and punch or chisel.
Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance
of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user.
Fisher is a mark owned by one of the companies in the Emerson Process Management business unit of Emerson Electric Co. Emerson Process Management,
Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not
to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are
governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such
products at any time without notice.
Emerson Process Management
Marshalltown, Iowa 50158 USA
Sorocaba, 18087 Brazil
Chatham, Kent ME4 4QZ UK
Dubai, United Arab Emirates
Singapore 128461 Singapore
www.Fisher.com
20
E 2002, 2015 Fisher Controls International LLC. All rights reserved.
Instruction Manual
D103042X012

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents