SERVICE TEST PROGRAM
ADC
TUNER
TEST
TEST
N
SOURCE
Button pressed?
Y
Display shows
"ADC1 Value"
(Input Line - Key0)
N
SOURCE
Button pressed?
Y
copied to the RAM (see Table 1)
Display shows
"ADC2 Value"
(Input Line - Key1)
N
SOURCE
Button pressed?
Y
Display shows
"ADC3 Value"
(Input Line - AmNTC)
N
SOURCE
Button pressed?
Y
Display shows
"ADC4 Value"
(Input Line - Option)
N
9
Button pressed?
Y
ADC Test is used for checking the ADC inputs
to the microprocessor.
The display shows an ADC value between 0
and 255 for an input signal between 0 and 5V.
Note :
If the ADC value on the NTC line is below 69,
the set will go to standby mode because the
temperature is too high.
3-1
To start service test program
hold T & SOURCE
plugging in the mains cord
QUARTZ
TEST
N
N
PROG
CLOCK/TIMER
Button pressed?
Button pressed?
Y
Y
Display Tuner Version
Display shows
"ccc"
32K
Output on Quartz-Test-Pin
pin 19 of uP = 2048Hz
N
PROG
Button pressed?
N
CLOCK/TIMER
Button pressed?
Y
Service frequencies are
Y
Tuner works normally except:
Display shows
PROGRAM button
12M
Output on Quartz-Test-Pin
pin 19 of uP = 2,929.6875Hz
N
Disconnect
Mains cord ?
9
N
Button pressed?
Y
Y
Service Mode left
USA
Europe
Oversea
PRESET
"USA"
"OSE"
"EUR"
1
87.5MHz
87.5MHz
87.5MHz
2
108MHz
108MHz
108MHz
3
531kHz
530kHz
531/530kHz*
4
1602kHz
1700kHz
1602/1700kHz*
5
558kHz
560kHz
558/560kHz*
6
1494kHz
1500kHz
1494/1500kHz*
98MHz
7
87.5MHz
87.5/98MHz*
87.5MHz
8
87.5MHz
87.5MHz
87.5MHz
9
87.5MHz
87.5MHz
10
87.5MHz
87.5MHz
87.5MHz
11
98MHz
87.5MHz
98/87.5MHz*
Table 1
Note: * Depending on the selected grid frequency (9 or 10kHz).
By holding the "SOURCE" and "PROG" buttons depressed
while switching on the Mains supply, the tuning grid frequency
is toggled between 9kHz and 10kHz for the Oversea (/21)
version.
depressed while
S refers to Service Mode
Display shows the
ROM version
V refers to Version
"S-Vyy"
(Main menu)
yy refers to Software version number of the uProcessor
(counting up from 01 to 99)
DISPLAY
TEST
N
BII
Button pressed?
Y
Display shows Figure 1
and switch all LEDs on
(see Table 2 - Pattern 1)
N
BII
Button pressed?
Y
Display shows Figure 2
and switch alternate LEDs on
(see Table 2 - Pattern 2)
N
BII
Button pressed?
Y
Display shows Figure 3
and switch all LEDs off
(see Table 2 - Pattern 3)
N
9
Button pressed?
Y
LEDs
Pattern 1
Pattern 2
Pattern 3
SACD
ON
OFF
STANDBY / ECO POWER
GREEN
RED
LCD BACKLIGHT
ON
ON
Table 2
Published in Heiloo, Holland.
3-1
Figure 1
Figure 2
Figure 3
TEST
Activated with ACTION
T
EEPROM TEST
A test pattern will be sent to the EEPROM.
"PASS" is displayed if the uProcessor read back
the test pattern correctly, otherwise "FAIL" will be
9 to Exit
displayed.
OFF
S
EEPROM FORMAT
Load default data. Display shows "NEW" for 1 second.
TEST
Caution!
OFF
All presets from the customer will be lost!!
ON
Pressing this button will toggle between the status
AUTO STANDBY
CENTER -
TOGGLE
(RC)
"AUTO STANDBY ON" and "AUTO STANDBY OFF".
The status will scroll once across the Display.
ROTARY
Rotary Volume
Display shows value for 2 seconds.
ENCODER TEST
Knob
Values increases or decreases in steps of 1 until
0 (Volume Min.) or 40 (Volume Max.) is reached.
LEAVE SERVICE