Checking Flow
Indication LED only operates in trickle charging mode.
START
Is the voltage
at R226 1.2V?
YES
Is LED working?
YES
LED will work properly
NO
Check the soldering of R225 or Q 401
NO
Check the soldering of Q200,
R218, LD200, R226
- 93 -