Schumacher Electric SI-82-6 Owner's Manual page 34

Table of Contents

Advertisement

Available languages

Available languages

PROBLEM
Ammeter reading
stays high.
Ammeter reads less
than selected charge
rate when charging
a discharged battery.
The charger is
making an audible
clicking sound.
Charger makes a
loud buzz or hum.
POSSIBLE CAUSE
Battery is severely discharged.
Wrong battery voltage.
Extension cord is too long or
wire gauge is too small.
Weak cell or sulfated plate in
battery.
Battery is only partially
discharged.
Circuit breaker is cycling.
Battery is defective.
Shorted battery cables or clips.
Severely discharged battery, but
otherwise it is a good battery.
Reverse connections at battery.
Transformer laminations vibrate
(buzz).
Shorted Diode Assembly or
Output Rectifier Assembly (hum).
Continue charging battery for two
more hours. If problem continues
have the battery checked.
Verify the voltage settings on the
charger are correct.
Use a shorter or heavier gauge
extension cord.
A sulfated battery will eventually
take a normal charge if left
connected. If the battery will not
take a charge, have it checked.
Continue to charge the battery.
The settings may be wrong. Check
the charger settings.
Have the battery checked.
Circuit breaker cycles when current
draw is too high. Check for shorted
cables or clips and replace if
necessary.
The battery may not want to accept
a charge due to a run-down state.
Allow charging to continue until
battery has a chance to recover
sufficiently to take a charge. If more
than 20 minutes, stop charging and
have the battery checked.
Shut the charger off and correct the
lead connections.
No problem, this is a normal
condition.
Have charger checked by a
qualified technician.
• 34 •
REASON/SOLUTION

Advertisement

Table of Contents
loading

This manual is also suitable for:

Si-70maSi-1275a

Table of Contents