Kenwood Ez700SR Service Manual page 15

Hide thumbs Also See for Ez700SR:
Table of Contents

Advertisement

conducted into the following 3 steps : 0 ⇔ 5 ⇔ 10. (Initial
value : 7)
Back up current measurement
When reset with ACC OFF (or with backup is ON) MUTE ter-
minal goes OFF after 2 seconds, instead of 15 seconds as is
normally the case. (At that moment, the CD mechanism is not
operating.)
Special display when all indicators are lighted up
When the preset key is pressed with all indicators lighted up in
All OFF mode, the following will be displayed.
q Key
• Version display (8 digits month, date, hour,
minute)
(Display) SYS xxxxxxxx
w Key
• Serial number display (8 digits)
(Display) SNo xxxxxxxx
e Key
• Short-push : Number of power ON hours display
(ALL OFF hours not counted.)
• Long-push of 2 seconds during Number of power
ON hours display : Number of power ON hours
is cleared
(Display) PonTim xxxxx
r Key
• Short-push : CD operation time display
• Long-push of 2 seconds during CD operation
time display : CD operation time is cleared.
(Display) CDTim xxxxx
t Key
• Short-push : Number of CD EJECT times
display
• Long-push of 2 seconds during number of CD
EJECT times display : number of CD EJECT
times is cleared.
(Display) EjeCnt xxxxx
y Key
• Short-push : Number of PANEL open/close times
display
• Long-push of 2 seconds during Number of
PANEL open/close times display : Number of
PANEL open/close times is cleared.
(Display) PnCnt xxxxxx
FM Key
• ROM correction version display
(Display) When effective : ROM R KKK
When not effective
(reading unsuccessful) : ROM R – – –
When not effective
(version different) : ROM R∗∗∗
TRACK-UP • Audio data initial value setting (Models with DC
Key
error detection function only)
(Display) AUDIO INIT
TEST MODE
MAX 60000 (hours)
MAX 60000 (hours)
MAX 60000 (times)
MAX 600000(times)
(K : Number)
Ez700SR/Ez900HDS
Others
• When q key is pressed, only during internal AUX, 2-ZONE
ON/OFF is effected. When ON, P/S dot is turned ON all the
time.
• When turning power ON, "CODE OFF/ON" will not be dis-
played.
• When booted up in Test Mode, normally 10 seconds LINE
MUTE prohibition time is shortened to 1 second.
• In the Test Mode, security code should not be written with
security jigs. (*1)
• In the Test Mode, serial number should not be written with
serial number writing jigs. (*1)
• In the Test Mode, even if OEM Display is not connected,
"OEM Display Out" output is not stopped.
(*1) Since this mode clears Test Mode by resetting, it is not
necessary to have it.
Frequency span switching (K/M Type)
Reset while pressing both q and t keys.
OEM compatible setting (Electronic volume des-
tination setting) (Ez500 only)
The models installed with S03F/E can cope with OEM models
by using the 2-pin on the microcomputer.
The following is the setting method.
IC2-TYPE0 IC2-TYPE1
(41pin)
(40pin)
q Third party model (Initial value)
Low
Low
w Third party model CRSC change
Low
High
e OEM model compatible CRSC
High
Low
r OEM model compatible CRSC
High
High
Security
• Forced power ON mode
It is possible to make the power come on for 30 minutes
only, even if the security is set (for both the simplified secu-
rity and security codes.). This is achieved by pressing Q
and r keys at the same time. Recoveries can be made
only by resetting after the elapse of 30 minutes. (Note : Use
of the above mode does not clear the security code. It's
purpose is to have the power come on temporarily.)
• How to clear the simplified security code (K-type only)
1. When it is requested to enter the code, while pressing
AUTO key, use long-push on the Track up key for 3 sec-
onds. (This makes – – – – disappear.)
2. Using the remote controller, input "KCAR".
Contents
change
& de-emphasis change
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ez900hds

Table of Contents