4.

Checking

4.1.

System check

Adjust the set point of the room unit HCW 80 to 30 °C.
If the room temperature is >30 °C the relay module
HC60NG is switched on.
Change the set point of the room unit HCW 80 to 5 °C.
If the room temperature is <5 °C the relay module
HC60NG is switched OFF.
4.2.

Radio transmission check

The room unit HCW 80 can send a test signal to the
assigned relay module HC60NG in order to test the signal
strength.
Keep the teach-in button of the HCW 80 pressed for at
least 15 sec until the red LED of the HCW 80 is OFF.
The HCW 80 is now in test mode and sends a test signal
every 5 sec.
The LED of the HCW 80 flashes briefly at every test
signal the HCW 80 is sending.
The field strength is indicated by flashing of the red LED of
the HC60NG (1 = sufficient, 5 = strong).
If the wireless communication is not successful optimise
the placement of the HCW 80.
The test mode is terminated automatically after
5 min. The test mode can also be terminated by
removing the batteries or by pressing the teach-
in button.
5.
Teach-in (singly provided
devices only)
The teach-in operation is required if the relay module
HC60NG and the room unit HCW 80 are not pre-bound e.g.
new single devices or product replacement.
5.1.
Assignment to the relay module
HC60NG
After the power up of the relay module HC60NG the red
LED will start to flash at 0.1 sec ON / 0.9 sec OFF.
If this is not the case set the HC60NG into the reset mode
see section 7 "Factory reset of relay module HC60NG".
Press and hold the teach-in button of the HC60NG for
5 sec to enter into the teach-in mode.
The red LED flashing at 0.5 sec ON / 0.5 sec OFF
confirms the teach-in mode has been entered.
Press the teach-in button of the HCW 80 to send the
binding signal to the HC60NG.
The red LED of the HC60NG is switched OFF to confirm
a successful teach-in operation.
The teach-in mode is terminated automatically after 5 min.
5.2.

Failed teach-in

If the teach-in has failed:
See section 5.1 "Assignment to the relay module
HC60NG".
Improve the data transfer.
Improving the data transfer
When selecting the operating site of each device ensure
that the distance to radio devices such as radio
headphones, cordless phones, etc. according to the DECT
standard amounts to at least 1 m.
Do not install the devices over metallic wall connecting
sockets and at least 30 cm away from the cover of the heat
generator.
Correct the installation site of the room unit HCW 80 if
necessary.
6.

Communication loss

When the RF communication is lost for a period of 1 h, the
red LED of the relay module HC60NG is ON to indicate that
no RF messages have been received during the last hour.
When RF communication is re-established the relay module
HC60NG will automatically return to normal operation mode.
See chapter
10.1 "Help with problems
and problem solving.
7.
Factory reset of relay
module HC60NG
Keep the button of the HC60NG pressed for at least
15 sec.
The resetting was successful when the red LED flashes
rapidly (1/9 ON/OFF).
After the factory reset the HC60NG looses the
communication with the HCW 80.
See section 5 "Teach-in (singly provided devices
only)" for new teach-in.