Receiver Section
Item
Condition
1. Seisitivity 1) CH : RX low (Wide/Narrow)
CH : RX center (Wide/Narrow)
CH : RX high (Wide/Narrow)
2) SSG output
: –118dBm (0.28µV) (Wide)
: –116dBm (0.35µV) (Narrow)
Mod : 1kHz
Dev : ±3.0kHz (Wide)
Dev : ±1.5kHz (Narrow)
2. Squelch 9 1) CH : RX low (Wide)
CH : RX center (Wide/Narrow)
CH : RX high (Wide)
2) SSG output
: –113dBm (0.5µV) (Wide)
: –112dBm (0.56µV) (Narrow)
Mod : 1kHz
Dev : ±3.0kHz (Wide)
Dev : ±1.5kHz (Narrow)
3. Squelch 1 1) CH : RX low (Wide)
CH : RX center (Wide/Narrow)
CH : RX high (Wide)
2) SSG output
: –120dBm (0.22µV) (Wide)
: –119dBm (0.25µV) (Narrow)
Mod : 1kHz
Dev : ±3.0kHz (Wide)
Dev : ±1.5kHz (Narrow)
Transmitter Section
Item
Condition
1. Frequency 1) CH : TX center
2) Transmit
2. High
1) CH : TX low
power
CH : TX low'
CH : TX center
CH : TX high'
CH : TX high
2) Transmit
3. Low
1) CH : TX low
power
CH : TX low'
CH : TX center
CH : TX high'
CH : TX high
2) Transmit
4. DQT
1) CH : TX low (Wide)
balance
CH : TC center (Wide/Narrow)
CH : TX high (Wide)
2) Transmit
ADJUSTMENT
Measurement
Test equipment
Terminal
SSG
ANT
Oscilloscope
EXT. SP
AF V.M
Distortion meter
Measurement
Test equipment
Terminal
Frequency counter
ANT
Power meter
Modulation analyzer
or Linear detector
(LPF : 3kHz)
Oscilloscope
TK-8102H
Adjustment
Parts
Method
Check
PC key
Adjust to open the squelch
Adjustment
Parts
Method
PC key
Adjust to center frequency
45W
25W
Adjust the waveform as below
Specifications/
Remarks
SINAD
: 12dB or higher
Specifications/
Remarks
Within ±100Hz
±1.0W
±1.0W