TK-8102H
Test Frequency (MHz)
Channel
TX
1 : Center
470.100
2 : Low
450.100
3 : High
489.900
4
470.000
5
470.200
6
470.400
PCB Section
Item
1. Setting
1) Power supply voltage
DC Power supply terminal : 13.6V
2. VCO lock
1) CH : TX high
voltage*
2) CH : RX high
3) CH : TX low
4) CH : RX low
3. IF coil
1) CH : RX center (Wide)
2) SSG output : –53dBm (501µV)
Mod : 1kHz, Dev : 3kHz
4. RF
1) CH : RX center (Wide)
bandpass
CH : RX low (Wide)
filter
CH : RX high (Wide)
2) Tra generator output : –30dBm
Connect the spectrum analyzer
to BPF terminal
* Adjustment of TX VCO lock voltage
1. Remove R814, R888 (fuse), R823 and R807 (all on component side).
2. Remove PCB from chassis.
3. Transmit and check voltage at [CV] point.
Warning : Do not transmit if step "1." is not complete.
4. Adjust of voltage can be done by tuning TC2.
K,M (F1)
16
ADJUSTMENT
K,M (F1)
RX
TX
470.050
498.600
450.050
485.100
489.950
511.900
470.000
498.500
470.200
498.700
470.400
498.900
Condition
Test equipment
Digital voltmeter
SSG
Digital voltmeter
Tra generator
Spectrum analyzer
K2 (F2)
RX
TX
498.550
502.600
485.050
485.100
511.950
519.900
498.500
502.000
498.700
502.200
498.900
502.400
Measurement
Terminal
Parts
CV
TC2
TC1
AFV
L22
ANT
TC3
BPF
TC5
K2,M2 (F2)
Fig. 1
M2 (F2)
RX
TX
502.550
415.100
485.050
400.100
519.950
429.900
502.000
415.000
502.200
415.200
502.400
415.400
Adjustment
Method
5.5V
5.5V
Check
3.2~3.3V (DC)
Adjust the BPF waveform
to Fig. 1
K3 (F3)
K3 (F3)
RX
415.050
400.050
429.950
415.000
415.200
415.400
Specifications/
Remarks
±0.1V
±0.1V
0.8V or more