2. Additional programes
2.3.1 Function of FUCS
Duration and limit table:
Phase Speed start Speed end
1
55 1/min
2
55 1/min
55 1/min
3
TSE-N 01.2000 R.K.
Time (duration)
115 1/min
from 0 to 200 sec Time out 1
115 1/min
from 0 to 140 sec
from 140 to 155 sec
from 155 to 170 sec
from 170 to 200 sec Time out 2
85 1/min
from 0 to 60 sec Time out 3
- 9 -
Unbalanced load limits
1,280
1,280
1,760
2,240
2,720
5,440
599 50 07-53/0