Ekol Clarity 30 Boiler Woodburning Stove INSTALLATION AND OPERATING INSTRUCTIONS. REF: Ekol Claity 30 Boiler Wood Version, MANUAL Version 1.1 MANUAL PUBLICATION DATE: 22.01.2014 Recommended as suitable for exemption under section 21 of The Clean Air Act 1993 for use within UK Smoke Control Area.
Ekol Clarity 30 Boiler Woodburning Stove, – INSTALLATION AND OPERATING INSTRUCTIONS. REF: Ekol Clarity 30 Boiler Wood Version, MANUAL VERSION 1.1 DATE: 22.01.2014 INTRODUCTION SAFETY Safety is the most important consideration when using and installing your stove. If not installed and used correctly, a house fire could result.
Page 3
The stove must not be installed within the specified minimum distances to combustible materials: A gap of at least 200mm needs to left between the stove and any combustible materials at the sides and 200mm to the rear. Adjacent walls should be of non-combustible materials and construction, preferably masonry or brickwork.
Page 4
(other than "authorised" fuels) have been exempted by an Order made and signed by the Secretary of State or Minister in the devolved administrations. “Ekol Clarity 30 Boiler” has been recommended as suitable for use in smoke control areas when burning seasoned wood and when used in accordance with these instructions..
Wood- All types of wood are suitable provided they are well seasoned, UNTREATED, and have a moisture level between 12% and 20%. For soft woods, typically they will need to have been left in suitable storage for 9+ months in order for the moisture to evaporate.
Page 6
2) Vent at back of stove, controlled by the thermostat is also a Primary air vent – the thermostat will allow air in initially but will close when upto temperature. When burning for longer periods, or when the stove is not supervised, all other vents shut be closed to minimum.
TOOLS The glove is provided for adjusting the air inlets and for opening the door when the stove is hot, as these knobs will heat up when in use. NOTE – all parts of the stove will become hot during use and care needs to be taken to avoid injury through burning. The tool handle provided is for removing the ash-pan.
Page 8
UK Clean Air Act 1993 - Smoke Control Areas The “Ekol Clarity 30 Boiler” wood burning stove has been recommended as suitable for use in smoke control areas when burning seasoned wood and when used in accordance with these instructions.. The air controls are factory set to allow a constant amount of combustion air, and must not be modified in anyway.
This stove is suitable for intermittent burning, and should not be used constantly for extended periods. Not suitable for overnight burning. Under certain abnormal weather conditions, e.g. down draughts, it may be difficult to get sufficient draw through the appliance to achieve good combustion. When this happens, the stove should not be used. CLEANING/MAINTENANCE Regular cleaning of the stove is essential for safety and efficiency.